background image

12

REV D

60706-231

 38.000 

 25.042 

2

1

3

 21.660 

5

9

8

6

ITEM NO.

PartNo

DESCRIPTION

QTY.

1

19022-200

RECEPTACLE  BOX ASSEMBLY

1

2

19022-055

ENGINE AND BASE ASSEMBLY

1

3

19022-011

DECAL INSTALLATION

1

4

100046-504 CARTON 30-50 PTO HSC/FOL TW 

43-1/2 X 27-3/8 X 26 ECT 80

1

5

21698-001

10-16 X .375 TORX SCREW

1

6

16249-000

.3125-18 FLANGE NUT

2

7

60706-231

OPERATOR MANUAL

1

8

526-000

5/16 FLAT WASHER

2

9

467-000

HHCS 5/16-18X.75  

2

REVISIONS

REV

IRN

DESCRIPTION

DATE

BY

APP'D

A

ORIGINAL

MVW

B

REDESIGNED RECEPTACLE BOX

6/20/12

PJY

MVW

C

3630

60706-231 ADDED

3/24/2015

KS

DRC

D

5271

REPLACED 473-000 WITH 467-000 ADDED 526-000

5/17/2016

RJD

ZJF

CHK'D BY

ENG APPR.

TITLE:

EC22000VE

DATE

DATE

DATE

DRAWN BY

MODEL:

PART:

PJY

THIS DRAWING CONTAINS 

PROPRIETARY

 INFORMATION BELONGING

 TO WINCO, 

UNAUTHORIZED USE IS 

PROHIBITED

ALL DIMESNIONS INCH

4/27/2012

EC22000VE/A

R

19022-000

19022-000

PJY

4/27/2012

TOLERANCE:

+/- 0.0625 DECIMAL

+/- 1 DEG ANGULAR

OUTLINE DRAWINGS

EC18000VE

EC22000VE

Summary of Contents for EC18000VE/D

Page 1: ...WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com INSTALLATION AND OPERATORS EC18000VE D EC22000VE A GENERATORS MANUAL...

Page 2: ...ou have selected a high quality precision engineered generator designed and tested to give you years of satisfactory service To get the best performance from your new generator it is important that yo...

Page 3: ...4 0 006 in Exhaust Valve Clearance 0 007 0 009 in Oil Capacity 78 80 oz 2 4 2 5 qts EC22000VE Starting Watts 22 000 22 000 22 000 22 000 Running Watts 19 000 19 000 19 000 19 000 Volts 120 240 120 208...

Page 4: ...resent a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C Do not smoke or use open flame near the generator...

Page 5: ...pliance or tool nameplates for the current and voltage to ensure compatibility Remember tha power utilized from C reduces the power available from both A and B and vice versa The EC22000 utilizes the...

Page 6: ...nt line This is to prevent the escape of fuel vapors in to the atmosphere 3 You need to have a primer bulb in the fuel line to prime the fuel from the tank to the fuel pump The vacuum fuel pump on the...

Page 7: ...th are going to vary depending on your installation These engines are all negative ground The positive battery cable must be connected to the open large terminal on the start solenoid This terminal ma...

Page 8: ...slightly lower voltage when the generator is loaded to its full capacity than when running no load The slight variation in speed also affects the frequency of the output current This frequency variati...

Page 9: ...ers mounted in some type of distribution panel This location will also be where you will install your neutral to ground bond You must wire four separate wires from the generator 2 hot 1 neutral and 1...

Page 10: ...e and remove the spark plug wire to prevent it from accidently being started b Remove oil drain plug at base of the engine Ref B and drain the oil into an approved container c Remove the oil lter Ref...

Page 11: ...p the air inlet screen on both the engine and generator free of any dirt or debris to ensure proper cooling At least yearly remove the blower housing on the engine and clean the chaff and dirt out of...

Page 12: ...6 FLAT WASHER 2 9 467 000 HHCS 5 16 18X 75 2 REVISIONS REV IRN DESCRIPTION DATE BY APP D A ORIGINAL MVW B REDESIGNED RECEPTACLE BOX 6 20 12 PJY MVW C 3630 60706 231 ADDED 3 24 2015 KS DRC D 5271 REPLA...

Page 13: ...13 REV D 60706 231 EC18000VE EC22000VE DISTRIBUTION WIRING SCHEMATICS 120 240 SINGLE PHASE 120 208 120 240 THREE PHASE 277 480 THREE PHASE...

Page 14: ...OW WYE THREE PHASE LO 120 208 VOLTS THREE PHASE HIGH WYE 277 480 VOLTS Page 14 0210 10 REV B 60706 197 EE PHASE AC WIRING H AND LOW WYE THREE PHASE LOW WYE 120 208 VOLTS E HIGH WYE S EC22000VE AC WIRI...

Page 15: ...REV B THREE PHASE AC WIRING D SINGLE PHASE AC WIRING SINGLE PHASE 120 240 VOLTS THREE PHASE D 120 240 VOLTS E PHASE AC WIRING DELTA E PHASE AC WIRING GLE PHASE 240 VOLTS THREE PHASE DELTA 120 240 VOLT...

Page 16: ...a particular purpose are limited to 24 months from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some states do not allow limitation on the duration of imp...