Copyright 2014, WINCO MFG., LLC
14
GENERAL MAINTENANCE
GAS SPRING RELEASE ADJUSTMENT:
If recline levers fail to operate properly, adjust the gas spring using the
instructions below.
1. Recline back of chair.
(See pg. 9 "Recline Chair From Attendant Position")
2. Return legrest to stored position.
3. Remove the seat (A) and position as shown (B).
(See pg. 10 "Seat Removal")
WARNING:
•
Seat is tethered to chair frame. Do not forcefully pull on seat.
Chairs equipped with heat and massage:
•
UNPLUG power cord from power source BEFORE removing seat,
cleaning, cleaning or servicing chair.
•
Chairs equipped with heat and massage - DO NOT attempt to
unplug wires.
•
ENSURE all wiring for seat is clear of all moving parts of the
mechanism before, during, and after re-installation of seat.
4. Locate the gas spring and loosen the nut on the gas spring using an
11/16" wrench.
5. Remove the opposite end of gas spring by removing the cotter & clevis
pin.
Proceed to step 6 or 7 depending on the necessary adjustment.
IMPORTANT:
•
DO NOT allow button on end of cylinder to depress while performing
this task.
4
3A
5
3B