W25Q80BV
- 60 -
8.
ELECTRICAL CHARACTERISTICS
8.1
Absolute Maximum Ratings
(1)
PARAMETERS
SYMBOL
CONDITIONS
RANGE
UNIT
Supply Voltage
VCC
–0.6 to +4.6
V
Voltage Applied to Any Pin
V
IO
Relative to Ground
–0.6 to VCC+0.4
V
Transient Voltage on any Pin
V
IOT
<20nS Transient
Relative to Ground
–2.0V to VCC+2.0V
V
Storage Temperature
T
STG
–65 to +150
°
C
Lead Temperature
T
LEAD
See Note
(2)
°
C
Electrostatic Discharge Voltage
V
ESD
Human Body Model
(3)
–2000 to +2000
V
Notes:
1. This device has been designed and tested for the specified operation ranges. Proper operation outside
of these levels is not guaranteed. Exposure to absolute maximum ratings may affect device reliability.
Exposure beyond absolute maximum ratings may cause permanent damage.
2. Compliant with JEDEC Standard J-STD-20C for small body Sn-Pb or Pb-free (Green) assembly and
the European directive on restrictions on hazardous substances (RoHS) 2002/95/EU.
3. JEDEC Std JESD22-A114A (C1=100pF, R1=1500 ohms, R2=500 ohms).
8.2
Operating Ranges
PARAMETER
SYMBOL
CONDITIONS
SPEC
UNIT
MIN
MAX
Supply Voltage
VCC
F
R
= 80MHz, f
R
= 50MHz
F
R
= 104MHz, f
R
= 50MHz
2.7
3.0
3.6
3.6
V
Ambient Temperature,
Operating
T
A
Commercial
Industrial / Auto. Grade 3
(1)
Industrial Plus / Auto. Grade 2
(1)
0
-40
-40
+70
+85
+105
°C
Note:
1.
For Industrial Plus, Automotive Grade 3 & 2 devices, please contact Winbond for more information.