W25Q80BV
Publication Release Date: Augest 01, 2012
- 63 - Revision G
8.5
AC Measurement Conditions
PARAMETER
SYMBOL
SPEC
UNIT
MIN
MAX
Load Capacitance
C
L
30
pF
Input Rise and Fall Times
T
R
, T
F
5
ns
Input Pulse Voltages
V
IN
0.2 VCC to 0.8 VCC
V
Input Timing Reference Voltages
IN
0.3 VCC to 0.7 VCC
V
Output Timing Reference Voltages
O
UT
0.5 VCC to 0.5 VCC
V
Note:
1. Output Hi-Z is defined as the point where data out is no longer driven.
Input and Output
Timing Reference Levels
Input Levels
0.8 VCC
0.2 VCC
0.5 VCC
Figure 39. AC Measurement I/O Waveform