W25Q16BV
Publication Release Date: July 08, 2010
- 53 - Revision F
12.
ELECTRICAL CHARACTERISTICS
12.1
Absolute Maximum Ratings
(1)
PARAMETERS SYMBOL
CONDITIONS
RANGE
UNIT
Supply Voltage
VCC
–0.6 to +4.0
V
Voltage Applied to Any Pin
V
IO
Relative to Ground
–0.6 to VCC+0.4
V
Transient Voltage on any Pin
V
IOT
<20nS Transient
Relative to Ground
–2.0V to VCC+2.0V
V
Storage Temperature
T
STG
–65 to +150
°
C
Lead Temperature
T
LEAD
See
Note
(2)
°
C
Electrostatic Discharge Voltage
V
ESD
Human Body Model
(3)
–2000 to +2000
V
Notes:
1. This device has been designed and tested for the specified operation ranges. Proper operation outside
of these levels is not guaranteed. Exposure to absolute maximum ratings may affect device reliability.
Exposure beyond absolute maximum ratings may cause permanent damage.
2. Compliant with JEDEC Standard J-STD-20C for small body Sn-Pb or Pb-free (Green) assembly and
the European directive on restrictions on hazardous substances (RoHS) 2002/95/EU.
3. JEDEC Std JESD22-A114A (C1=100pF, R1=1500 ohms, R2=500 ohms).
12.2
Operating Ranges
SPEC
PARAMETER SYMBOL
CONDITIONS
MIN MAX
UNIT
Supply Voltage
(1)
VCC
F
R
= 80MHz, f
R
= 50MHz
F
R
= 104MHz, f
R
= 50MHz
F
R
= 50MHz (for E3h command)
2.7
3.0
3.0
3.6
3.6
3.6
V
Ambient Temperature,
Operating
T
A
Commercial
Industrial
0
–40
+70
+85
°C
Note:
1. VCC voltage during Read can operate across the min and max range but should not exceed ±10% of
the programming (erase/write) voltage.