Washbasin fitting
WimTec LOFT
23
EN
LOFT
Function settings
Serves to rinse water supply lines in order to remove stagnant water that
accumulates during longer periods of disuse.
‘ON’ position:
Intelligent stagnation rinse is enabled.
‘OFF’ position:
Intelligent stagnation rinse is disabled (default setting).
Intelligent stagnation rinse:
DIP switch 4
ON
OFF
2 3 4 5 6
1
You can select one of two predefined stagnation rinse times (10 or 20 s).
‘ON’ position:
Stagnation rinse time is set to 20 s.
‘OFF’ position:
Stagnation rinse time is set to 10 s (default setting).
Stagnation rinse time:
DIP switch 5
ON
OFF
2 3 4 5 6
1
3 - 48 h
10 / 20 s
um 07:00 Uhr
um 07:00 Uhr
um 07:00 Uhr
Time interval
Can be set from 3 – 48 h at
the interval control, default
setting 24 h (see p. 18).
Intelligent stagnation rinse
If the fitting has not been
used for the set period, an
automatic flushing is perfor-
med for the duration (see
DIP 5) configured.