18 Washbasin fitting
WimTec LOFT
EN
LOFT
Configuring the functions
Setting controls
1. Interval control
for intelligent stagnation
rinse, default setting 24 h
(setting range 3 - 48 h).
2. Time control
for flushing stop time,
default setting 1 min
(setting range 10 s - 600 s).
Rule applies to all controls:
Move counterclockwise to
decrease the setting.
Move clockwise to
increase the setting.
!
Function activation – DIP switch 1–6:
DIP switch
Function
default setting
Description
1
Active range (ON =
15 cm
, OFF = 12 cm)
ON
Page 21
2
Cleaning stop
OFF
Page 21
3
Continuous flow
OFF
Page 22
4
Intelligent stagnation rinse
OFF
Page 23
5
Stagnation rinse time (ON = 20 s, OFF =
10 s
)
OFF
Page 23
6
Shut-off delay (ON = 3 s, OFF =
1 s
)
OFF
Page 24
DIP switches:
12
h
3
48
6
24
60
s
10
600
30
300
After removing the fitting housing
set the desired temperature at the
side screw by using a screwdriver.
Temperature setting (only at product variant HDVM - with hidden mixer):