background image

22    Washbasin fitting 

WimTec LOFT 

EN

LOFT 

Function settings

Enable the continuous flow function to fill the washbasin or a container.

‘ON’ position: 

Continuous flow function is enabled.

‘OFF’ position:

 

Continuous flow function is disabled (default setting).

Continuous flow:

DIP switch 3

ON

OFF

2 3 4 5 6

1

Enable continuous flow

 

Approach the infrared sensor 
with your hand. The sensor 
LED starts flashing. After  
flashing three times, conti-
nuous flow is enabled for the 
water arrest time configured.

Enable continuous flow if 
cleaning stop is enabled  
(DIP 2 + 3 = ON)

Approach the infrared sensor 
with your hand. 

 
The water flow starts and 
stops immediately after 5 
flashes of the sensor LED. 

 
After 3 further flashes the 
waterflow starts and conti-
nuous flow is enabled.

Disable continuous flow

Automatically after the water 
arrest time set at DIP switch 5 
(see page 18) has elapsed. 

 
To instantly end continuous 
flow, perform the same steps 
as used for ‘Enable  
continuous flow’.

 
After flashing 3 times the 
continuous flow is disabled.

3 x

3 x

5 x +

3 x 

um 07:00 Uhr

um 07:00 Uhr

um 07:00 Uhr

um 07:00 Uhr

Summary of Contents for LOFT HDK

Page 1: ...LOFT DE Montage und Bedienungsanleitung Assembly and operating instructions EN ...

Page 2: ... 049 WimTec LOFT HDVM Art Nr 123 913 123 937 Lieferumfang Armaturengehäuse mit Elektronikmodul 230 V Netzteil oder 9 V Batterie Magnetventil Anschlussschläuche Schmutzsiebaufsätze für Eckventil Befestigungsmaterial und Rückflussverhinderer bei Mischwasserausführung Wichtige Installationshinweise Die Montage und Installation darf nur durch einen konzessionierten Fachbetrieb gemäß DIN 1988 ÖVE ÖNORM...

Page 3: ...Seite Technische Daten 4 Legende 5 Einstellung der Funktionen 6 Montage 7 Funktion 8 Funktionsbeschreibung 9 Reichweite 9 Reinigungsstopp 9 Dauerlauf 10 Intelligente Freispül Automatik 11 Freispülzeit 11 Nachlaufzeit 12 LED Signale 12 Ersatzteile 13 ...

Page 4: ...ich automatisch Nah Ansprechbereich ca 3 cm Spülstoppzeit 10 s bis 10 min einstellbar Intelligente Freispül Automatik aktivierbar Spülintervall nach 3 h bis 48 h Nichtbenutzung Spüldauer 10 s oder 20 s Dauerlauf aktivierbar für die Dauer der Spülstoppzeit Reinigungsstopp aktivierbar für 3 min Fließdruck 0 05 bis 0 6 MPa 0 5 bis 6 bar Statischer Druck max 0 8 MPa 8 bar Wassertemperatur max 70 C max...

Page 5: ...be entfernen Danach Armaturenhaube abnehmen um Einstellregler des Elektro nik Moduls freizulegen 1 Intervall Regler 2 Zeit Regler 3 Dip Schalter 4 Status LED Abmessungen in mm Elektronik 169 Ø 50 Ø 33 117 140 max 45 15 125 Rückflussverhinderer mit Vorfilter 1 2 3 4 5 6 ON OFF 1 3 2 4 ...

Page 6: ...12 DIP Schalter Einstellregler 1 Intervall Regler für die intelligente Freispül Automatik 24 h voreingestellt 3 48 h einstellbar 2 Zeit Regler für die Spülstoppzeit 1 min voreingestellt 10 s 10 min einstellbar Einstellelemente Generell gilt für alle Regler Gegen den Uhrzeigersinn zum Reduzieren Im Uhrzeigersinn zum Erhöhen 12 h 3 48 6 24 Nach dem Abnehmen der Arma turenhaube die gewünschte Tem per...

Page 7: ...b Bei Batterievariante Batterie in Batteriemodul einsetzen und Steckverbindung zwischen Armatur und Modul herstellen Wasserzufluss öffnen 4 Automatischer Reichweitenabgleich Nach ca 5 s blinkt die LED 3 mal und die Armatur ist betriebs bereit Während des Reichweitenabgleichs nicht in den Sensorbereich fassen ACHTUNG Folgende Schritte unbe dingt in beschriebener Reihenfolge ausführen 1 2 3a 3b 4 Lu...

Page 8: ...gleich Nach Inbetriebnahme der Stromversorgung Dauer ca 5 s Wasserfluss startet Sobald der Benutzer vom Ansprechbereich der Infrarot sensorik erfasst wird Wasserfluss stoppt Wenn der Benutzer den An sprechbereich wieder verlässt oder nach Ablauf der einge stellten Spülstoppzeit ...

Page 9: ...FF 2 3 4 5 6 ON OFF 2 3 4 5 6 1 1 5 x 3 x Reinigungsstopp aktivieren Heranführen der Hand an den Infrarot Sensor Die LED im Sensor beginnt zu blinken und der Wasserfluss startet Nach 5x Blinken stoppt der Wasserfluss und der Rei nigungsstopp ist für 3 min aktiviert in dieser Zeit blinkt die LED 2x alle 3 s Reinigungsstopp deaktivieren automatisch Die Armatur geht nach 3 min automatisch wieder in d...

Page 10: ...der Dauerlauf für die eingestellte Spülstoppzeit aktiviert Dauerlauf aktivieren wenn Reinigungsstopp aktiv Dip 2 3 ON Heranführen der Hand an den Infrarot Sensor Der Wasserfluss startet und wird nach 5 maligem Blinken der Status LED wieder beendet Nach weiteren 3 Blinkimpul sen startet der Wasserfluss erneut und der Dauerlauf ist aktiviert Dauerlauf deaktivieren Automatisch nach Ablauf der am DIP ...

Page 11: ...halter 4 ON OFF 2 3 4 5 6 1 Es kann zwischen 2 vordefinierten Freispülzeiten 10 s bzw 20 s gewählt werden Stellung ON Die Freispülzeit beträgt 20 s Stellung OFF Die Freispülzeit beträgt 10 s voreingestellt Freispülzeit DIP Schalter 5 ON OFF 2 3 4 5 6 1 3 48 h 10 20 s Zeitintervall Einstellbar am Intervall Regler von 3 48 h 24 h voreingestellt siehe Seite 6 Intelligente Freispül Automatik Wird die ...

Page 12: ...Stellung ON Nachlaufzeit beträgt 3 s Stellung OFF Nachlaufzeit beträgt 1 s voreingestellt Nachlaufzeit DIP Schalter 6 ON OFF 2 3 4 5 6 1 Beschreibung der LED Signale Signal Beschreibung 1x Blinken alle 5 s niedriger Batterie Zustand 2x Blinken alle 3 s Reinigungsstopp aktiv 1x Blinken Magnetventil wird geöffnet 2x Blinken Magnetventil wird geschlossen ...

Page 13: ...1 7 Senkschraube 109 115 8 Armaturenunterteil Mischwasser 109 122 Kaltwasser 109 221 9 Elektronikmodul 108 873 10 Mischerwelle 109 139 11 Adapter 121 919 12 Mischergriff 121 926 13 Befestigungsset 109 160 14 Anschlussschlauch 350 mm Länge 230 291 500 mm Länge 230 307 15 Rückflussverhinderer 230 314 inkl Vorfilter 16 Netzteil 230 V 101 065 17 Batteriemodul inkl 9 V Batterie 231 380 inkl 6 V Batteri...

Page 14: ...21 049 WimTec LOFT HDVM with hidden mixer Art no 123 913 123 937 Delivery scope Tap housing with electronic module 230 V power unit or 9 V battery magnetic valve connnection hoses dirt filter attachment for corner valve mounting material and reflux preventers at variant with mixer Important installation notes Mounting and installation may only be performed by a qualified service provider in accord...

Page 15: ...ifications 16 Legend 17 Configuring the functions 18 Assembly 19 Function 20 Function settings 21 Active range 21 Cleaning stop 21 Continuous flow 22 Intelligent stagnation rinse 22 Stagnation rinse time 23 Shut off delay 24 LED signals 24 Replacement parts 25 ...

Page 16: ...e 6 V Active range automatic Close active range approx 3 cm Flushing stop from 10 s 10 min adjustable Intelligent stagnation rinse activatable flushing intervall after 3 h to 48 h of non usage flushing time 10 s or 20 s Continuous flow activatable for the flushing stop time Cleaning stopp activatable for 3 min Flow rate 0 05 0 6 MPa 0 5 6 bar Static pressure max 0 8 MPa 8 bar Water temperature max...

Page 17: ...x 45 15 125 Reflux preventer with pre filter Remove mixing handle and lock screw Afterwards remove upper fitting to access the elec tronics setting elements 1 Interval control 2 Time control 3 DIP switches 4 Status LED Dimension in mm Electronics 1 2 3 4 5 6 ON OFF 1 3 2 4 ...

Page 18: ...rease the setting Function activation DIP switch 1 6 DIP switch Function default setting Description 1 Active range ON 15 cm OFF 12 cm ON Page 21 2 Cleaning stop OFF Page 21 3 Continuous flow OFF Page 22 4 Intelligent stagnation rinse OFF Page 23 5 Stagnation rinse time ON 20 s OFF 10 s OFF Page 23 6 Shut off delay ON 3 s OFF 1 s OFF Page 24 DIP switches 12 h 3 48 6 24 60 s 10 600 30 300 After rem...

Page 19: ...ting open the water valve 3b Battery version Place the battery into the battery module and connect the battery to the fitting open the water valve 4 Automatic range adjustment After approx 5 s the LED flashes 3 times and the fitting is operational Do not trigger the sensor when performing the range adjustment ATTENTION Perform the following steps in the order indicated 1 2 3a 3b 4 Air and water ti...

Page 20: ...djustment After connection to a power supply Duration approx 5 s Water starts flowing As soon as the infrared sensor detects the user within the sensor range Water stops flowing Once the user clears the sensor range or after the configured water arrest time has elapsed ...

Page 21: ...tch 2 ON OFF 2 3 4 5 6 ON OFF 2 3 4 5 6 1 1 3 x 3 x 5 x Enable cleaning stop Approach the infrared sensor with your hand The sensor LED starts flashing and water begins to flow from the faucet After flashing 5 times the water flow is stopped and the cleaning stop is enabled for 3 min In this time the LED flashes 2 times every 3 s Disable cleaning stop automatically The fitting will resume normal o...

Page 22: ...three times conti nuous flow is enabled for the water arrest time configured Enable continuous flow if cleaning stop is enabled DIP 2 3 ON Approach the infrared sensor with your hand The water flow starts and stops immediately after 5 flashes of the sensor LED After 3 further flashes the waterflow starts and conti nuous flow is enabled Disable continuous flow Automatically after the water arrest t...

Page 23: ...IP switch 4 ON OFF 2 3 4 5 6 1 You can select one of two predefined stagnation rinse times 10 or 20 s ON position Stagnation rinse time is set to 20 s OFF position Stagnation rinse time is set to 10 s default setting Stagnation rinse time DIP switch 5 ON OFF 2 3 4 5 6 1 3 48 h 10 20 s Time interval Can be set from 3 48 h at the interval control default setting 24 h see p 18 Intelligent stagnation ...

Page 24: ...r 3 s ON position Shut off delay is 3 s OFF position Shut off delay is 1 s default setting Shut off delay DIP switch 6 ON OFF 2 3 4 5 6 1 LED signals Signal description Signal Description 1x flash every 5 s low battery 2x flashes every 3 s cleaning stop active 1x flash opening magnetic valve 2x flash closing magnetic valve ...

Page 25: ...109 061 7 Countersink screw 109 115 8 Fitting base part Mixed water 109 122 Cold water 109 221 9 Electronics module 108 873 10 Mixing shaft 109 139 11 Adapter 121 919 12 Mischer lever 121 926 13 Mounting set 109 160 14 Connection tubing 350 mm long 230 291 500 mm long 230 307 15 Return flow valve 230 314 incl pre filter 16 Power supply 230 V 101 065 17 Battery module incl 9 V battery 231 380 incl ...

Page 26: ...26 Washbasin fitting WimTec LOFT EN LOFT ...

Page 27: ...Washbasin fitting WimTec LOFT 27 EN LOFT ...

Page 28: ...www wimtec com WimTec Sanitärprodukte GmbH p A 3325 Ferschnitz Freidegg 50 AUSTRIA t 43 0 7473 5000 f 43 0 7473 5000 500 m verkauf wimtec com i www wimtec com Auflage 28 04 2015 Art Nr 1002165 ...

Reviews: