background image

  

© by WilTec Wildanger Technik GmbH  

Item 61950 

Page 6 

 

http://www.WilTec.de

 

http://www.aoyue.eu   

   

05 2021

-1

 

http://www.teichtip.de

 

 

Do not cut rebates or grooves without fitting a suitable guard, e. g., a tunnel-type guard, over 
the saw table. 

 

Circular saws must not be used for slotting jobs (cutting grooves which end in the workpiece). 

 

When  transporting  the  electric  tool,  only  use  the  transport  devices.  Never  use  the  protective 
devices for handling or transport. 

 

Make sure that the upper part of the saw blade is covered during transport, e. g., by the protec-
tive device. 

 

Be sure to only use spacers and spindle rings specified by the manufacturer as suitable for the 
intended purpose. 

 

The floor around the machine must be level, clean and free of loose particles, such as chips 
and cutting residues. 

 

Always stand to the side of the saw blade when working with the saw. 

 

Do not remove any cutting residues or other parts of workpieces from the cutting zone while the 
machine is running and the saw unit is not at rest. 

 

Make sure that the machine is always secured on a workbench or a table if at all possible. 

 

Support long workpieces (e. g., with a roller table) to prevent them sagging at the end of a cut. 

 

Attention!

 Never remove loose splinters, chips or jammed pieces of wood while the saw blade 

is running. 

 

Switch off the machine to troubleshoot or remove jammed pieces of wood. 

First disconnect 

the main power plug.

 

 

Refitting, including adjusting and measuring works, and cleaning must be carried out only when 
the motor is switched off. 

Disconnect the main power plug first.

 

 

Before switching on again, ensure that keys and adjustment tools have been removed. 

 

Warning!

 This electric tool generates an electromagnetic field during operation. This field can 

impair active or passive medical implants under certain conditions. In order to prevent the risk 
of serious or  deadly  injuries, we recommend that persons with medical implants consult with 
their physician and the manufacturer of the medical implant prior to operating the electric tool. 

 

Safety precautions for the handling of saw blades

 

 

 

Only use insertion tools if you are familiar with their use. 

 

Observe the maximum speed. The maximum speed specified on the insertion tool may not be 
exceeded. If specified, observe the speed range. 

 

Observe the motor/saw blade direction of rotation. 

 

Do  not  use  any  insertion  tools  with  cracks.  Sort  out  cracked  insertion  tools.  Repairs  are  not 
permitted. 

 

Clean grease, oil and water off of the clamping surfaces. 

 

Do not use any loose reducing rings or bushes for the reducing of holes on saw blades. 

 

Make sure that fixed reducer rings for securing the insertion tool have the same diameter and 
have at least 

1

/

3

 of the cutting diameter. 

 

Make sure that fixed reducer rings are parallel to each other. 

 

Handle insertion tool with caution. They are ideally stored in the originally package or special 
containers.  Wear  protective  gloves  in  order  to  improve  grip  and  to  further  reduce  the  risk  of 
injury. 

 

Prior to the use of insertion tools, make sure that all protective devices are properly fastened. 

 

Prior to use, make sure that the insertion tool meets the technical requirements of this electric 
tool and is properly fastened. 

 

Only use the supplied saw blade for sawing operations in wood, materials similar to wood, plas-
tics and non-ferrous metals (except for magnesium and alloys containing magnesium). 

 

 

Summary of Contents for 61950

Page 1: ...ting instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...vice wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschwei...

Page 3: ...y for damage or accidents which arise due to a failure to follow these instructions and the safety instructions Safety regulations Warning Do read all safety regulations and instructions Any errors made in following the safety regulations and instructions may result in an electric shock fire and or serious injury Keep all safety regulations and instructions in a safe place for future use Safe work...

Page 4: ...ication and for tool replacement Check the connection cable of the electric tool regularly and have it replaced by a recog nised specialist when damaged Check the extension cables regularly and replace them when they are damaged Keep the handle dry clean and free of oil and grease Pull the plug out of the socket During non use of the electric tool or prior to maintenance and when replacing tools s...

Page 5: ... of becoming hearing impaired a respiratory protection to avoid the risk of inhaling harmful dust Wear gloves when handling saw blades and rough materials Carry saw blades in a container whenever practical Wear goggles Sparks generated during work or splinters chippings and dust coming from the device can lead to loss of eyesight Connect a dust collecting device to the electric tool when sawing wo...

Page 6: ... ensure that keys and adjustment tools have been removed Warning This electric tool generates an electromagnetic field during operation This field can impair active or passive medical implants under certain conditions In order to prevent the risk of serious or deadly injuries we recommend that persons with medical implants consult with their physician and the manufacturer of the medical implant pr...

Page 7: ... by WilTec Wildanger Technik GmbH Item 61950 Page 7 http www WilTec de http www aoyue eu 05 2021 1 http www teichtip de Layout and items supplied Layout ...

Page 8: ...erload protection switch 21b Longitudinal struts 12 Hand wheel 22a Ring wrench 10 21 mm 13 Adjusting and locking grip 22b Ring wrench 10 13 mm Items supplied Please check that the article is complete as specified in the scope of delivery If parts are missing please contact our service centre or the sales outlet where you made your purchase at the latest within 5 work ing days after purchasing the ...

Page 9: ...ble width extension 2 8 Rubber feet 4 16a Parallel stop 15 Saw blade guard 4 Cross stop 7 Extractor adapter 5 Push stick 9 Ring wrench 10 21 mm 22a Ring wrench 10 13 mm 22b Hexagonal screw 36 19 Hexagonal screw nut 28 20 Riving knife Proper use The bench type circular saw is designed for the slitting and cross cutting only with the cross stop of all types of timber commensurate with the machine si...

Page 10: ...e liable for any changes made to the device nor for any damage resulting from such changes Even when the device is used as prescribed it is still impossible to eliminate certain residual risk factors The following hazards may arise in connection with the construction and design of the device contact with the saw blade in the uncovered saw zone reaching into the running saw blade cut injuries kick ...

Page 11: ...ing style to suit the appliance Do not overload the appliance Have the appliance serviced whenever necessary Switch the appliance off when it is not in use Caution Residual risks Even if you use this electric power tool in accordance with instructions certain residual risks cannot be rules out The following hazards may arise in connection with the construction and layout of the device damage to lu...

Page 12: ...lade 3 on the riving knife 6 so that the screw fits through the hole in the riving knife Do not tighten the screw 19 too far the blade guard 4 must be able to move freely To remove the saw blade guard proceed in reverse order Warning The guard hood 4 must always be lowered over the workpiece before you begin to cut Setting in the riving knife Danger Pull out the power plug Set the riving knife 6 t...

Page 13: ...h extension Use the screws 19 and nuts 20 to fasten the table width extensions 8 loosely to the saw table 1 Screw the supports loosely onto the saw housing and onto the table width extensions Align the table width extensions level with the saw table Finally re tighten all screws Using the saw On off switch To turn the saw on press the green I button Wait for the blade to reach its maximum speed of...

Page 14: ...e fixing handle Turn the handle to set the desired angle on the scale Lock the fixing handle again in the required angle position Overload protection switch The motor of this appliance is protected against overload by an overload protection switch 11a If the rated current is exceeded the overload switch switches the appliance off After a short cooling off time the appliance can be switched back on...

Page 15: ...ts Bevel cuts must always be used using the parallel stop 15 Set the blade to the desired angle Set the parallel stop in accordance with the workpiece width and height Carry out the cut in accordance with the work piece width Cross cuts Slide the cross stop 7 into one of the grooves in the table and adjust to the required angle If you also want to tilt the blade use the groove which prevents your ...

Page 16: ... have the carbon brushes checked only by a qualified electrician Danger The carbon brushes should not be replaced by anyone but a qualified electrician Maintenance There are no parts inside the device which require additional maintenance Ordering replacement parts Please quote the following data when ordering replacement parts type of machine article number of the machine identification number of ...

Page 17: ... by WilTec Wildanger Technik GmbH Item 61950 Page 17 http www WilTec de http www aoyue eu 05 2021 1 http www teichtip de Illustrative images concerning the assembly ...

Page 18: ... by WilTec Wildanger Technik GmbH Item 61950 Page 18 http www WilTec de http www aoyue eu 05 2021 1 http www teichtip de ...

Page 19: ...European countries with a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste device By contributing to the correct disposal of this article you protect the environment and the health of your f...

Reviews: