2. Suction port, suction strainer and/or impeller
clogged
-
Clean the suction port, suction strainer and/or
impeller
3. Impeller stiff
-
Switch off the hydraulics, secure them against
being switched back on again and free the
impeller
4.
Inadmissible levels of gas in the fluid
-
Consult the factory
5. Incorrect direction of rotation
-
Replace 2 phases of the mains supply
6. Signs of wear
-
Replace worn parts
7. Shaft bearing defective
-
Consult the factory
8. Hydraulics are installed under tension
-
Check installation, use rubber compensators if
necessary
Fault: Mechanical seal leak, sealing chamber
monitoring reports a fault or shuts down the
unit
1. Condensation water build-up due to extended
storage and/or temperature fluctuations
-
Operate the hydraulics briefly (max. 5 min)
without pencil electrode
2. Increased leakage when running in new mechan-
ical seals
-
Change the oil
3. Defective pencil electrode cables
-
Replace pencil electrode
4. Mechanical seal is defective
-
Replace the mechanical seal and contact the
plant!
Further steps for troubleshooting
If the points listed here do not rectify the fault,
contact the Wilo customer service. They can help
you as follows:
•
Telephone and/or written support from the Wilo
customer service
•
On-site support from the Wilo customer service
•
Inspection or repair of the hydraulics at the plant
Please note that you may be charged for some
services provided by our customer service! For
more details, please contact the Wilo customer
service.
10. Appendix
10.1. Tightening torques
Rust-free screws (A2/A4)
Thread
Tightening torque
Nm
kp m
M5
5.5
0.56
M6
7.5
0.76
M8
18.5
1.89
M10
37
3.77
Rust-free screws (A2/A4)
Thread
Tightening torque
Nm
kp m
M12
57
5.81
M16
135
13.76
M20
230
23.45
M24
285
29.05
M27
415
42.30
M30
565
57.59
Geomet-coated screws (strength 10.9) with Nord-Lock
disc
Thread
Tightening torque
Nm
kp m
M5
9.2
0.94
M6
15
1.53
M8
36.8
3.75
M10
73.6
7.50
M12
126.5
12.90
M16
155
15.84
M20
265
27.08
10.2. Spare parts
Spare parts can be ordered from the Wilo
customer service. To avoid return queries and
incorrect orders, the serial and/or article number
must always be supplied.
Subject to technical modifications without prior
notice!
Summary of Contents for Wilo-Rexa NORM
Page 2: ...Fig 2 Fig 1 A B 8 9 10 2 4 4 7 5 5 3 1 2 7 1 6 3 6...
Page 3: ...Fig 3B Fig 3A 1...
Page 4: ...Fig 4 8 2 4 7 5 3 1 6 Fig 5 1 Rexa NORM M15 77 2140 1400 370 790 860 370 36 29...
Page 7: ...Fig 7 Fig 6 A A A A 2 4 4 5 5 5 5 5 5 3 1 S1 S1 X X Y Y Z Z Fz Mz My Mx Fy Fx...
Page 8: ...Fig 9 Fig 8 2 3 1 2 4 5 3 1...
Page 9: ...Fig 11 Fig 10 F2 F1 M1 M2...
Page 10: ...Fig 13 Fig 12 D D L...
Page 30: ......
Page 31: ......