en
42
WILO SE 2019-11
6.8
Collective run signal (SBM) – orange terminal block
➜ Fig. 23
An integrated collective run signal is applied at the SBM terminals as
a potential-free normally open contact. Contact load:
▪ Permitted minimum: SELV 12 V AC / DC, 10 mA
▪ Permitted maximum: 250 V AC, 1 A, AC1 / 30 V DC, 1 A
6.9
Connecting and removing the Wilo-Connector
WARNING
Risk of fatal electrical shock!
▪ Never connect or remove live plugs!
Connect
➜ Fig. 15 to 20
Spring clips: WAGO “Cage Clamp”.
Remove
➜ Fig. 21
▪ Remove the Wilo-Connector only using a suitable tool!
6.10
Bluetooth radio interface
The pump has a Bluetooth interface for connecting to mobile
devices. Using the Wilo-Smart Connect app and a smartphone, you
can operate and adjust the pump and read out pump data.
Bluetooth is active by factory default and can, if required, be deac-
tivated via the Settings/Device settings/Bluetooth menu.
▪ Frequency band: 2400 MHz – 2483.5 MHz
▪ Maximum radiated transmission power: < 10 dBm (EIRP)
7
Put into operation
7.1
Venting
1. Fill and vent the system correctly.
To vent the rotor chamber if required, activate the pump venting
function in the pump menu.
7.2
Pump operation
Description of operating elements
➜ Fig. 3 and 4
Pos. Name
Explanation
3.1
Graphic dis-
play
Provides information about settings and
pump status.
Self-explanatory user interface for setting
the pump.
3.2
Green LED in-
dicator
LED lights up, pump supplied with power.
There are no warnings and no faults.
3.3
Blue LED in-
dicator
Pump is influenced externally via an inter-
face, e.g. by:
• Bluetooth remote control
• Setpoint specification via analogue input
AI1 or AI2
• Intervention of building automation via
control input DI1 / DI2 or bus communica-
tion
• Flashes with active twin-head pump con-
nection
Summary of Contents for Stratos MAXO
Page 27: ...en 9 2 Batteries rechargeable batteries 47...
Page 49: ...fr 9 2 Pile accumulateur 70...
Page 73: ...nl 9 2 Batterijen en accu s 94...
Page 166: ...el 9 187 9 1 187 9 2 188...
Page 167: ...el Wilo Stratos MAXO D Z 167 1 1 1 T Internet QR www wilo com stratos maxo om 1 2 1 3 1 4...
Page 171: ...el Wilo Stratos MAXO D Z 171 1 40 C WILO SE...
Page 173: ...el Wilo Stratos MAXO D Z 173 3 4 3 5 SSM SBM 5...
Page 175: ...el Wilo Stratos MAXO D Z 175 5 5 1 5 2 1 2 3 4 5 3 1 EN 12828 2 3 4 5 6 10 cm 7 Fig 7...
Page 178: ...el 178 WILO SE 2019 11 Fig 13 5 7 1 6 6 1 6 2 LED SELV SELV SSM SBM...
Page 185: ...el Wilo Stratos MAXO D Z 185 1 1 1 CIF 2 3 4 5 No Flow Stop OFF 6 7 8 8 Homescreen...
Page 188: ...el 188 WILO SE 2019 11 9 2 Stratos MAXO Wilo www wilo recycling com...
Page 190: ...tr 9 2 Pil ak 210...
Page 213: ...sv 9 2 Batteri 232...
Page 235: ...no 9 2 Engangsbatteri oppladbart batteri 254...
Page 257: ...fi 9 2 Paristo akku 277...
Page 279: ...da 9 2 Batteri akkumulator 299...
Page 302: ......