English
18
WILO SE 05/2014
CAUTION! Risk of material damage!
Impermissible substances in the fluid can destroy the pump. Abra-
sive solids (e.g. sand) increase pump wear.
Pumps without an Ex-rating are not suitable for use in potentially
explosive areas.
• The correct use of the pump/installation also includes following
these instructions.
• Any other use is considered to be incorrect use.
5
Product information
5.1
Type key
The type key consists of the following elements:
5.2
Technical data
When ordering spare parts, make sure to state all the information
given on the pump and motor rating plates.
5.3
Scope of delivery
• SiFlux
• Switchgear
• Installation instructions: system, pump and switchgear
• Safety instructions
6
Description and function
6.1
General description
The system is a compact installation which is supplied completely
piped and ready-for-connection. The only connections that have to
be made are for suction and discharge and also the power mains.
6.2
Description of the product
Mechanic and hydraulic installation components (Fig. 2, 3 and 4)
The compact installation is mounted on a steel base frame with vibra-
tion absorbers (pos. 3). It consists of a group of 3 or 4 in-line pumps
with electronics (pos. 1), which are combined by means of a supply
manifold pipe (pos. 4) and a delivery manifold pipe (pos. 5).
Example:
SiFlux-21-IL-E 65/160-7,5/2-SC-16-T4
SiFlux
Multi-pump system for closed HVAC installations
21
2 operating pumps + 1 standby pump
IL-E
65/160-7,5/2
Pump type
(see Installation and operating instructions of th
pump)
SC
Type of switchgear
16
Maximum operating pressure
T4
Three-phase supply voltage 400V
Property
Value
Remarks
Maximum permissible operating pressure
16 bar
Maximum permissible fluid temperature
+120 °C
Ambient temperature min./max.
0 °C to +40 °C
Electrical connection
3~230 V, 50 Hz
3~400 V, 50 Hz