26
9.6 Recommended spare parts
In case of standard operation, we recommend
the following list of spare part regarding the
period of functioning.
For 2 years of normal operation:
Mechanical seal or Packing, ball bearings and
the different gasket required for the
dismounting of the pump.
For 3 years of normal operation:
Mechanical seal or Packing, ball bearings
and the different gasket required for the
dismounting of the pump, wear rings and
their nuts. For the pumps equipped with
Gland packing, include the gland plate and
lubrication spacer.
For 5 years of normal operation:
Take the same lot of part as for 3 years and
add the shaft and impeller.
The maintenance of the split case pumps is
easier than other pump types. Then in order
to facilitate this operation we strongly
recommended purchasing a batch of part
with the pump in order to reduce the shut
down timing.
It is strongly recommended to purchase the
original spares parts from Wilo. In order to
avoid any mistake we invite you to supply with
any spare parts demand, the information
mentioned on the data plate of the pump
and / or motor.