Appendix
en
Installation and operating instructions Wilo-EMU TR/TRE 50-2 ... 120-1
47
TR/TRE 50-2...
TR/TRE 60-2...
TR 75-2...
TR 80-1 ...
TR/TRE 90-2...
TR 120-1...
ATEX approval
Motor winding: Temperature limiter
o
o
o
o
o
o
Motor winding: Temperature controller and lim-
iter
•
•
•
•
•
•
FM/CSA-Ex rating
Motor winding: Temperature limiter
•
•
•
•
•
•
Motor winding: Temperature controller and lim-
iter
o
o
o
o
o
o
Legend
− = not available/possible, o = optional, • = standard
13.3.4.1 Monitoring of motor winding
DANGER
Risk of explosion due to overheating of the motor!
If the temperature limiter is connected incorrectly, there is a risk of explosion due to
overheating of the motor! Always connect the temperature limiter to a manual re-
activation lock. This means that a “release button” must be manually activated!
Depending on the version of the thermal motor monitoring, the following triggering
status must occur when the threshold value is reached:
ƒ
Temperature limiter (1 temperature circuit):
When the threshold is reached, deactivation
with reactivation lock
must take place!
ƒ
Temperature controller and limiter (2 temperature circuits):
When the threshold for the low temperature is reached, the motor can deactivate
with automatic reactivation. When the threshold for the high temperature is
reached, the motor must deactivate
with reactivation lock
!
CAUTION! Motor damage due to overheating! In the event of automatic reactiva-
tion, comply with the specifications for the maximum switching frequency and
switching break!
Connection of the thermal motor monitoring
ƒ
Connect the bimetallic strip via an evaluation relay. Relay “CM-MSS” is recommen-
ded for this. The threshold is preset.
Connection values: max. 250 V(AC), 2.5 A, cos φ = 1
ƒ
Connect the PTC sensor via an evaluation relay. Relay “CM-MSS” is recommended
for this. The threshold is preset.
13.3.4.2 Pre-chamber monitoring (external
electrode)
ƒ
Connect the external pencil electrode via an Ex-rated evaluation relay! Relay
“XR-4…” is recommended for this.
The threshold is 30 kOhm.
ƒ
The connection must be made using an intrinsically safe circuit!
13.3.4.3 Frequency converter operation
ƒ
Type of converter: Pulse-width modulation
ƒ
Continuous duty: 30 Hz up to rated frequency (50 Hz or 60 Hz).
ƒ
Min. switching frequency: 4 kHz
ƒ
Max. overvoltages on the terminal board: 1350 V
ƒ
Output current on the frequency converter: max. 1.5 times rated current
ƒ
Max. overload time: 60 s
ƒ
Torque applications: quadratic curve
Speed/torque curves required are available on request!
ƒ
Observe additional measures with regard to EMC regulations (choice of frequency
converter, filters, etc.).
ƒ
Never exceed the rated current or rated speed of the motor.