1.  Introduction

1.1.  About this document

The language of the original operating instruc-
tions is German. All other languages of these 
instructions are translations of the original oper-
ating instructions.
This manual is divided into individual sections, 
which are listed in the table of contents. Each 
section has a heading which clearly describes its 
content.
A copy of the EC declaration of conformity is a 
component of these operating instructions.
If a technical modification is made on the designs 
named there without our agreement, this decla-
ration loses its validity.

1.2.  Personnel qualifications

All personnel who work on or with the lifting unit 
must be qualified for such work; electrical work, 
for example, may only be carried out by a qualified 
electrician. All personnel must be of legal age.
Operating and maintenance personnel must also 
observe national accident prevention regulations.
It must be ensured that personnel have read and 
understood the instructions in this operating and 
maintenance handbook; if necessary, this manual 
must be ordered from the manufacturer in the 
required language.
This lifting unit is not intended for use by persons 
(including children) with reduced physical, senso-
ry or mental capabilities, or lack of experience and 
knowledge, unless they have been given super-
vision or instruction concerning use of the lifting 
unit by a person responsible for their safety.
Children should be supervised to ensure that they 
do not play with the lifting unit.

1.3.  Copyright

This operating and maintenance manual has been 
copyrighted by the manufacturer. The operating 
and maintenance manual is intended for use by 
installation, operating and maintenance person-
nel. It contains technical regulations and drawings 
which may not be reproduced or distributed, 
either completely or in part, or used for purposes 
of competition, or shared with others without the 
express consent of the manufacturer. Illustrations 
may differ from the original and serve only as 
example illustrations of the lifting unit.

1.4.  Subject to change

The manufacturer reserves the right to make 
technical modifications to units or components. 
This operation and maintenance manual refers to 
the lifting unit indicated on the title page.

1.5.  Warranty

In general, the specifications in the current “gen-
eral terms and conditions” apply for the warranty. 
You can find these here: 
www.wilo.com/legal
Any deviations must be contractually agreed and 
shall then be given priority.

1.5.1.  General

The manufacturer is obliged to correct any de-
fects found in the lifting units it sells, provided 
that the defects meet one or more of the follow-
ing requirements:

• The defects are caused by the materials used 

or the way the product was manufactured or 
designed.

• The defects were reported in writing to the man-

ufacturer within the agreed warranty period.

• The lifting unit was used only as prescribed.
• All monitoring devices are connected and were 

tested before commissioning.

1.5.2.  Warranty period

The duration of the warranty period is stipulated 
in the “general terms and conditions”.
Any deviations must be contractually agreed.

1.5.3.  Spare parts, add-ons and modifications

Only genuine spare parts from the manufacturer 
may be used for repairs, replacements, add-ons 
and modifications. Unauthorised add‑ons and 
modifications or the use of non‑original spare 
parts can seriously damage the lifting unit and/or 
seriously injure personnel.

1.5.4.  Maintenance

The prescribed maintenance and inspection 
work should be carried out regularly. This work 
may only be carried out by qualified, trained and 
authorised personnel.

1.5.5.  Damage to the product

Damage and malfunctions that endanger safety 
must be eliminated immediately by trained per-
sonnel. The lifting unit may only be operated if it 
is in proper working order.
In general, repairs should only be carried out by 
Wilo customer service.

1.5.6.  Exclusion from liability

No warranty claims will be accepted or liability 
will be assumed for lifting unit damage if any of 
the following items apply:

• Inadequate configuration by the manufacturer 

due to the information provided by the operator 
or customer being insufficient or incorrect

• Non-compliance with safety instructions and 

working instructions as specified in this operating 
and maintenance manual

• Improper use
• Incorrect storage and transport
• Improper assembly/dismantling
• Insufficient maintenance
• Incorrect repairs
• Inadequate construction site or construction work
• Chemical, electrochemical and electrical influ-

ences

• Wear

This means the manufacturer’s liability excludes 
all liability for personal injury, material damage or 
financial losses.

Summary of Contents for DrainLift S

Page 1: ...uctions fr Notice de montage et de mise en service es Instrucciones de instalaci n y funcionamiento it Istruzioni di montaggio uso e manutenzione pt Manual de Instala o e funcionamento nl Inbouw en be...

Page 2: ...Fig 3 Fig 2 Fig 5 Fig 1 1 3 3 2 4 4 5 5 6 9 9 6 6 6 7 7 8 1 1 1 2 2 40 60 mm 1 2 3 4 5 7 6 10 20 mm 1 1 1 1 1 3 2 3 3 4 4 4 5 5 1 2 3 4...

Page 3: ...Fig 7 Fig 6 Fig 8 Fig 4 45 290 45 60 45 290 45 60 45 45 45 80 min 180 mm 1 50 1 2 3 4 5 5 1 15 mm 1 2 1 3 2...

Page 4: ...0Hz 1 brown yellow green white grey blue brown black 2 3 4 5 L1 L2 L3 PE 3 400V 50 60Hz L1 L L2 N PE 1 230V 50 60Hz 1 230V 50Hz 30 15 0 Seconds ON 100 K DIP 1 2 3 4 5 6 7 PE SSM 1 2 3 7 8 9 4 5 6 GL W...

Page 5: ......

Page 6: ...key 30 3 7 Scope of delivery 30 3 8 Accessories optionally available 30 4 Transportation and storage 31 4 1 Delivery 31 4 2 Transport 31 4 3 Storage 31 4 4 Return delivery 32 5 Installation 32 5 1 Gen...

Page 7: ...he lifting unit indicated on the title page 1 5 Warranty In general the specifications in the current gen eral terms and conditions apply for the warranty You can find these here www wilo com legal An...

Page 8: ...erator must report any faults or irregulari ties that occur to a line manager immediately The end user must shut down the equipment im mediately if defects occur that represent a safety risk These inc...

Page 9: ...e for ensuring that regulations are observed 2 6 Fluids The lifting unit chiefly collects and pumps waste water containing faeces As a result changing to a different fluid is not possible Use in drink...

Page 10: ...is ready for connection as a single pump system Fig 1 Description 1 Collection reservoir 6 Inlet DN 40 2 Inspection opening 7 Ventilation connection 3 Level control 8 Pressure connection 4 Motor 9 Fa...

Page 11: ...id grain size 40 mm Motor data Mains connection U f See rating plate Power consumption P1 See rating plate Rated power P2 See rating plate Rated current IN See rating plate Speed n See rating plate Ac...

Page 12: ...tions and deposits building up in the collection reservoir on the level control and the pump hydraulics DANGER due to toxic substances Flushing through the lifting unit contami nates the flushing wate...

Page 13: ...tallation types Stationary dry well installation in buildings and pump chambers 5 3 Installation DANGER due to overpressure Exceeding the application limits can result in excessive pressure in the col...

Page 14: ...the lifting unit These must be attached to the reservoir Lifting gear must be technically approved Also refer to all regulations rules and laws for working with heavy and suspended loads Wear appropri...

Page 15: ...oo small the discharge pipe or the flange connector must be shortened If the distance is too large the hose section can not be properly secured 6 Align the flexible connecting hose to the centre and u...

Page 16: ...ing unit The min connection height is 180 mm NOTE When using the DN 40 connection on the lon gitudinal side it is always possible that drainage problems will arise for physical reasons The inlet must...

Page 17: ...sitions of the indi vidual DIP switches Read the installation and operating instructions for the fitted switchgear 5 4 4 Connecting an external alarm signal The switchgear is fitted with a buzzer in t...

Page 18: ...rating conditions The lifting unit is only allowed to be operated under the following conditions Max intake h 600 l Max suction head 5 m Max permitted pressure in pressure pipe 1 5 bar Max fluid tempe...

Page 19: ...gency operation DANGER due to toxic substances During emergency operation there is poten tial for contact with fluids that represent a health hazard The following points must be observed without fail...

Page 20: ...e seal 5 Disconnect the connection between the non re turn valve and the pressure port 6 Disconnect the connection between the ventila tion pipe and the ventilation connection and pull the pipe up off...

Page 21: ...Have the mains connection checked elec trician 5 Running on two phases Renew defective fuse electrician Check the electrical connection electrician 6 Motor does not start because there is no voltage C...

Page 22: ......

Page 23: ...Pioneering for You WILO SE Nortkirchenstra e 100 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...