6.4.3.4 Installing the cover and restoring
the sub-floor
1
2
3
4
5
6
Fig. 12:
Installing the tank cover
1
Filling material
2
Tank cover with tile frame
3
O-Ring in the upper sealing bead
4
Concrete layer
5
Screed layer
6
Ceramic tiling
✓
Lifting unit installed.
✓
Pit filled with filling material.
✓
Collar installed (mandatory when watertight concrete used!)
1.
Insert the O-Ring in the upper sealing bead in the neck of the tank.
2.
Apply a lubricant to the O-Ring.
3.
Take the floor drain out of the tile frame.
4.
Insert tank cover with tile frame into the neck of the tank.
5.
Align the tile frame with the upper surface of the tiles in the operating space and fix the
tank cover in place.
CAUTION! Ensure the O-ring is in the correct position!
6.
Restore the sub-floor: Fill in the concrete and screed layer.
NOTICE! After the concrete and screed have hardened, fill in any hollow spaces with
suitable material!
7.
Restore the tile flooring.
▶
The lifting unit is now completely installed.
6.4.3.5 Final tasks
NOTICE
Only affix floor drain following function test!
The floor drain is fixed into the tile frame with silicone. If the floor drain is
removed after the silicone has set, the old silicone must be removed
completely and the floor drain re-installed.
3
1
2
2
Fig. 13:
Installing the floor drain
1
Tile frame
2
Line of silicone
3
Floor drain
✓
Tiling work complete.
✓
Function test carried out.
1.
Apply a line of silicone around the tile frame.
2.
Allow the silicone to dry briefly (max. 5 mins).
3.
Insert the floor drain into the tile frame and lightly press it in.
4.
Wait 24 hours before walking on the floor drain.
▶
The floor drain is now installed.
6.4.4
Floor-mounted installation work
steps
The lifting unit is installed using the following steps:
•
Preparatory tasks.
•
Install the lifting unit.
Lay the connection cable, connect the piping, install buoyancy safeguards.
6.4.4.1 Preparatory tasks
•
Unpack the lifting unit.
•
Remove the securing mechanisms.
•
Check the scope of delivery.
•
Check all components are in proper working condition.
CAUTION! Do not install defective components! Defective components can lead to
system failures!
•
Place accessories to one side and keep them for later use.
Summary of Contents for DrainLift BOX
Page 2: ...DrainLift BOX https qr wilo com 742...
Page 3: ...3 Chinese 4 English 26...
Page 5: ...zh CHS Wilo DrainLift BOX Ed 06 2022 10 5 1 1 1 1 2 WILO SE 2022 1 3 Wilo 1 4 Wilo 2 2 1...
Page 6: ...zh CHS 6 Wilo DrainLift BOX Ed 06 2022 10 1 2 2...
Page 8: ...zh CHS 8 Wilo DrainLift BOX Ed 06 2022 10 2 7 2 8 2 9 3 3 1 DIN EN 12050 EN 12050 2...
Page 51: ......