Installation and operating instructions Wilo-Drain STS 65

15

7.1.2 Transportable wet well installation (Fig. 3   

In the case of a portable wet well installation, 
secure the pump in the pit to prevent accidents 
and wandering (e.g. secure the chain with slight 
pre-tension).
NOTE: When used in a sump without a firm base, 
the pump must be put on a sufficiently large plate 
or hung from a rope or a chain in a suitable posi-
tion.

7.1.3 Stationary dry well installation, for pump with 

cooling jacket only (Fig 4)    

• The fixed pipe connections on the pressure side 

must be provided on site.

• The weight of pipes and fittings must not be car-

ried by the pump and compensators and must be 
intercepted through the use of suitable fixings.

• A resonance-free pump installation must be 

ensured on site. The pipes must be supported at 
suitable intervals to prevent inadmissible vibra-
tions. The use of suitable compensators is recom-
mended for decoupling the pump.

7.2 Electrical connection

DANGER! Risk of fatal injury!
If the electrical connection is not made properly, 
there is a risk of fatal injury from an electric 
shock.

• Only allow the electrical connection to be made 

by an electrician approved by the local electric-
ity supplier and in accordance with the local reg-
ulations in force.

• Follow the installation and operating instruc-

tions for the pump, level control device and 
other accessories

.

Preparation of the electrical connection

• Make sure that the type of current and voltage of 

the mains connection corresponds to the details 
on the name plate.

• Protect the connection on the mains side: 16 A, 

slow or automatic fuse with C characteristic.

• Earth the system according to regulations.
• Use  a 

 30 mA residual current circuit-breaker.

• Use an isolating device with a min. 3 mm contact 

opening to isolate from the mains.

• Connect the pump.

7.2.1 Pump with single-phase motor (1~230 V)

• The motor is already wired with the condenser box 

at the works. The mains connection is made at 
terminals L1, N, PE of the terminal box.

• According to DIN EN / IEC 61000-3-11, the pump 

is designed with a power of 1.5 kW for operating 
on a power supply mains with a system impedance 
Zmax on the house connection of maximum 0.118 
(0.086) Ohm with a maximum number of 10 (20) 
connections.

• Number of connections, see 5.2 of the Technical 

data.
NOTE: If the mains impedance and the number of 
connections per hour is greater than the values 
specified, because of the unfavourable mains 
connections, the pump may lead to temporary 
voltage drops and also to disturbing voltage fluc-
tuations, or flickering.
Therefore, measures may be necessary before the 
pump can be operated correctly on this connec-
tion.
The necessary information must be obtained from 
the electricity supply company and the manufac-
turer.

7.2.2 Pump with three-phase motor (3~400 V):

• The use of a residual current circuit-breaker is 

recommended.

• The switchbox for the pump(s) is available as an 

accessory.

CAUTION! Danger of property damage!
Risk of damage through incorrect electrical con-
nection.
If the switchbox is provided by the customer on 
site, the following requirements of the electric-
ity supply companies must be met

.

• P

2

 

 4 kW: direct starting:

• Set the motor protection switch to the nominal 

current of the motor according to the name 
plate.

• For the thermal monitoring of the motor, a 

standard evaluation device can be used to con-
nect the thermal winding contact. Connect with 
230 V AC, max. 1 A, recommended: 24V DC

Pos. Description of the 

component

Pos. Description of the 

component

4

Bend

12

Hose connection

6

Chain

13

Fixed coupling 
(instead of item 12)

9

Floor supporting foot

14

Hose coupling 
(instead of item 12)

11

Counter-flange

15

Pressure hose

Pos. Description of the 

component

Pos. Description of the 

component

2

Non-return valve

17

Installation set

3

Gate valve

18

Compensator

Summary of Contents for Drain STS 65

Page 1: ...o e funcionamento GR TR Montaj ve kullanma k lavuzu S Monterings och sk tselanvisning FIN Asennus ja k ytt ohje H Be p t si s zemeltet si utas t s PL Instrukcja monta u i obs ugi CZ N vod k mont i a o...

Page 2: ...Fig 1 Fig 2 Fig 3 Fig 4 1 2 5 6 7 8 9 10 2 3 4 5 6 10 9 8 7 1 6 min min 1 4 5 2 3 1 min min 9 4 13 14 15 6 11 15 11 12 4 min min 2 18 18 3 17 17...

Page 3: ...51 TR Montaj ve kullanma k lavuzu 59 S Monterings och sk tselanvisning 67 FIN Asennus ja k ytt ohje 75 H Be p t si s zemeltet si utas t s 83 PL Instrukcja monta u i obs ugi 91 CZ N vod k mont i a obsl...

Page 4: ...ust have the appro priate qualifications for this work 2 3 Danger in the event of non observance of the safety instructions Non observance of the safety instructions can result in risk of injury to pe...

Page 5: ...ust be operated submerged without cooling jacket submerged or on the surface with cooling jacket DANGER Mortal danger through electric shock The pump must not be used for draining swim ming pools gard...

Page 6: ...te See name plate Max delivery head See name plate Operating mode S1 1 Without cooling jacket Motor submerged With cooling jacket Motor on surface Operating mode intermittent duty S3 2 Motor on surfac...

Page 7: ...General The installation site for the pump must be free of frost The shaft must be cleared of coarse material such as rubble before setting up and starting the pump Thepressurepipemusthavethenominaldi...

Page 8: ...mains Connect the pump 7 2 1 Pump with single phase motor 1 230 V The motor is already wired withthe condenser box at the works The mains connection is made at terminals L1 N PE of the terminal box A...

Page 9: ...level must not drop below the permit ted minimum switch off level See the installation and operating instructions for the level control device The switch off point must be chosen so that the operating...

Page 10: ...ow rate according to the follow ing formula With the horizontal section A the following gen eral formula can be used Q m h 36 x A m2 x h cm t s 9 3 Oil change WARNING Risk of injury The pumps are heav...

Page 11: ...voltage Check the wires and fuses or switch auto matic fuses in the distribution station back on Rotor blocked Clean the housing and impeller if still blocked replace the pump Fuses condenser defectiv...

Page 12: ...jectives of the low voltage directive 2006j95jEC are realized according annex I No 1 5 1 of the EC Machinery directive 2006j42jEC Les objectifs protection de la directive basse tension 2006j95jEC sont...

Page 13: ...strojn za zen 98 37 ES bzw 2006 42 ES dyrektyw maszynow WE 98 37 WE bzw 2006 42 WE EC 98 37 EG bzw 2006 42 EG C le t kaj c se bezpe nosti stanoven ve sm rnici o elektrick ch za zen ch n zk ho nap t js...

Page 14: ...lint Budapest T 36 23 889500 wilo wilo hu Ireland WILO Engineering Ltd Limerick T 353 61 227566 sales wilo ie Italy WILO Italia s r l 20068 Peschiera Borromeo Milano T 39 25538351 wilo italia wilo it...

Page 15: ...263 Dortmund T 0231 4102 7900 T 01805 W I L O K D 9 4 5 6 5 3 F 0231 4102 7126 Erreichbar Mo Fr von 7 17 Uhr Wochenende und feiertags 9 14 Uhr elektronische Bereitschaft mit R ckruf Garantie Kundendie...

Reviews: