Installation and operating instructions Wilo-Drain STS 65

11

Installation and operating instructions

1 General

About this document

These installation and operating instructions are 
an integral part of the product. They must be kept 
readily available at the place where the product is 
installed. Strict adherence to these instructions is 
a precondition for the proper use and correct 
operation of the product.
These installation and operating instructions cor-
respond to the relevant version of the product and 
the underlying safety standards valid at the time 
of going to print.

2 Safety

These operating instructions contain basic infor-
mation which must be adhered to during installa-
tion and operation. For this reason, these 
operating instructions must, without fail, be read 
by the service technician and the responsible 
operator before installation and commissioning.
It is not only the general safety instructions listed 
under the main point "safety" that must be 
adhered to but also the special safety instructions 
with danger symbols included under the following 
main points.

2.1 Indication of instructions in the operating 

instructions

Symbols:
General danger symbol

Danger due to electrical voltage

NOTE 

Signal words:
DANGER!
Acutely dangerous situation
Non-observance results in death or the most 
serious of injuries.
WARNING!
The user can suffer (serious) injuries. 'Warning' 
implies that (serious) injury to persons is proba-
ble if this information is disregarded.
CAUTION!
There is a risk of damaging the pump/installa-
tion. 'Caution' implies that damage to the prod-
uct is likely if the information is disregarded.

NOTE: Useful information on using the product. It 
draws attention to possible problems.

2.2 Personnel qualifications

The installation personnel must have the appro-
priate qualifications for this work.

2.3 Danger in the event of non-observance of the 

safety instructions

Non-observance of the safety instructions can 
result in risk of injury to persons and damage to 
pump/installation. Non-observance of the safety 
instructions can result in the loss of any claims to 
damages.
In detail, non-observance can, for example, result 
in the following risks :

• Failure of important pump/installation functions,
• Failure of required maintenance and repair proce-

dures

• Danger to persons from electrical, mechanical and 

bacteriological influences,

• Property damage

2.4 Safety instructions for the operator

The existing directives for accident prevention 
must be adhered to.
Danger from electrical current must be eliminated. 
Local directives or general directives [e.g. IEC, VDE 
etc.] and local power supply companies must be 
adhered to.
Risks through mechanical or bacteriological 
effects must be prevented. Local conditions and 
guidelines relating to sewage technology must be 
adhered to.

2.5 Safety instructions for inspection and 

installation work

The operator must ensure that all inspection and 
installation work is carried out by authorised and 
qualified personnel, who are sufficiently informed 
from their own detailed study of the operating 
instructions.
Work to the pump/installation must only be car-
ried out when at a standstill.

2.6 Unauthorised modification and manufacture of 

spare parts

Modifications to the pump/installation are only 
permissible after consultation with the manufac-
turer. Original spare parts and accessories author-
ised by the manufacturer ensure safety. The use of 
other parts can nullify the liability from the results 
of their usage.

2.7 Incorrect use

The operating safety of the supplied pump/instal-
lation is only guaranteed for conventional use in 
accordance with Section 4 of the operating 
instructions. The limit values must on no account 
fall under or exceed those specified in the cata-
logue/data sheet.

Summary of Contents for Drain STS 65

Page 1: ...o e funcionamento GR TR Montaj ve kullanma k lavuzu S Monterings och sk tselanvisning FIN Asennus ja k ytt ohje H Be p t si s zemeltet si utas t s PL Instrukcja monta u i obs ugi CZ N vod k mont i a o...

Page 2: ...Fig 1 Fig 2 Fig 3 Fig 4 1 2 5 6 7 8 9 10 2 3 4 5 6 10 9 8 7 1 6 min min 1 4 5 2 3 1 min min 9 4 13 14 15 6 11 15 11 12 4 min min 2 18 18 3 17 17...

Page 3: ...51 TR Montaj ve kullanma k lavuzu 59 S Monterings och sk tselanvisning 67 FIN Asennus ja k ytt ohje 75 H Be p t si s zemeltet si utas t s 83 PL Instrukcja monta u i obs ugi 91 CZ N vod k mont i a obsl...

Page 4: ...ust have the appro priate qualifications for this work 2 3 Danger in the event of non observance of the safety instructions Non observance of the safety instructions can result in risk of injury to pe...

Page 5: ...ust be operated submerged without cooling jacket submerged or on the surface with cooling jacket DANGER Mortal danger through electric shock The pump must not be used for draining swim ming pools gard...

Page 6: ...te See name plate Max delivery head See name plate Operating mode S1 1 Without cooling jacket Motor submerged With cooling jacket Motor on surface Operating mode intermittent duty S3 2 Motor on surfac...

Page 7: ...General The installation site for the pump must be free of frost The shaft must be cleared of coarse material such as rubble before setting up and starting the pump Thepressurepipemusthavethenominaldi...

Page 8: ...mains Connect the pump 7 2 1 Pump with single phase motor 1 230 V The motor is already wired withthe condenser box at the works The mains connection is made at terminals L1 N PE of the terminal box A...

Page 9: ...level must not drop below the permit ted minimum switch off level See the installation and operating instructions for the level control device The switch off point must be chosen so that the operating...

Page 10: ...ow rate according to the follow ing formula With the horizontal section A the following gen eral formula can be used Q m h 36 x A m2 x h cm t s 9 3 Oil change WARNING Risk of injury The pumps are heav...

Page 11: ...voltage Check the wires and fuses or switch auto matic fuses in the distribution station back on Rotor blocked Clean the housing and impeller if still blocked replace the pump Fuses condenser defectiv...

Page 12: ...jectives of the low voltage directive 2006j95jEC are realized according annex I No 1 5 1 of the EC Machinery directive 2006j42jEC Les objectifs protection de la directive basse tension 2006j95jEC sont...

Page 13: ...strojn za zen 98 37 ES bzw 2006 42 ES dyrektyw maszynow WE 98 37 WE bzw 2006 42 WE EC 98 37 EG bzw 2006 42 EG C le t kaj c se bezpe nosti stanoven ve sm rnici o elektrick ch za zen ch n zk ho nap t js...

Page 14: ...lint Budapest T 36 23 889500 wilo wilo hu Ireland WILO Engineering Ltd Limerick T 353 61 227566 sales wilo ie Italy WILO Italia s r l 20068 Peschiera Borromeo Milano T 39 25538351 wilo italia wilo it...

Page 15: ...263 Dortmund T 0231 4102 7900 T 01805 W I L O K D 9 4 5 6 5 3 F 0231 4102 7126 Erreichbar Mo Fr von 7 17 Uhr Wochenende und feiertags 9 14 Uhr elektronische Bereitschaft mit R ckruf Garantie Kundendie...

Reviews: