NOTE: When drafting a maintenance plan, expen-
sive repairs can be avoided and a fault-free oper-
ation of the system can be achieved with a 
minimum of maintenance effort. The Wilo-after-
sales service is available for commissioning and 
maintenance work. A maintenance report must be 
issued.

9.2 Maintenance procedure

• Open pump sump, station and ventilate.
• Inspect the inside visually

• Deposits on the pump, sump floor and on the  

accessories

• Shut off sewage inlet(s) (e.g. with air plugs)
• Measure the pump delivery head when Q = 0 m³/h. 

• If the flow rate of the pump drops by more than 

10 %, lift it out of the sump. Then check the 
impeller and the pump housing for wear.

• Check the sump level.
• Drain the sump manually until slurping operation.

• Check the sump floor for deposits.
• Clean the sump if there are major deposits.

• Fill the sump and carry out a trial run.
• If the delivery head cannot be measured

• Wait until the sump is filled and the pump starts 

up

• Measure the time between switching on and off 

(t) and also the drop in level (

h).

• Calculate the flow rate according to the follow-

ing formula.

With the horizontal section A, the following gen-
eral formula can be used:
Q [m³/h] = 36 x A [m

2

] x 

h [cm] / t [s] 

9.3 Oil change

WARNING! Risk of injury!
The pumps are heavy and can fall over.
People may be injured if the pump is not prop-
erly secured during maintenance work.
Always check the stability of the pump and use 
suitable hoisting gear.
WARNING! Risk of injury!
An overpressure may prevail in the sealing 
chamber/separation chamber.
If the oil drain plug is undone, hot oil may spurt 
out under pressure and cause injury or scalding. 
Before changing the oil, put on protective gog-
gles and undo the oil drain plug with care.
WARNING! Danger to the environment

!

Oil may leak out if the pump is damaged or dis-
mantled.
This can damage the environment.
Avoid damage and adopt suitable measures to 
take up the oil.

Have the oil changed once a year or after 1000 
operating hours during a maintenance operation.

• Provide suitable hoisting gear depending on the 

weight of the pump.

• Oil type and fill volumes: see 5.2 Technical data.

NOTE: When you change the oil, the old oil and 
water have to be disposed of as hazardous waste! 

Sump type

Formula

WB 100

Q [m³/h] = 28,3 x 

h [cm] / t [s]

WB 150

Q [m³/h] = 63,6 x 

h [cm] / t [s]

WB 200

Q [m³/h] = 113,1 x 

h [cm] / t [s]

Square sump Q [m³/h] = 36 x A [m] x B [m] x 

h [cm] / t [s]

Summary of Contents for Drain STS 65

Page 1: ...o e funcionamento GR TR Montaj ve kullanma k lavuzu S Monterings och sk tselanvisning FIN Asennus ja k ytt ohje H Be p t si s zemeltet si utas t s PL Instrukcja monta u i obs ugi CZ N vod k mont i a o...

Page 2: ...Fig 1 Fig 2 Fig 3 Fig 4 1 2 5 6 7 8 9 10 2 3 4 5 6 10 9 8 7 1 6 min min 1 4 5 2 3 1 min min 9 4 13 14 15 6 11 15 11 12 4 min min 2 18 18 3 17 17...

Page 3: ...51 TR Montaj ve kullanma k lavuzu 59 S Monterings och sk tselanvisning 67 FIN Asennus ja k ytt ohje 75 H Be p t si s zemeltet si utas t s 83 PL Instrukcja monta u i obs ugi 91 CZ N vod k mont i a obsl...

Page 4: ...ust have the appro priate qualifications for this work 2 3 Danger in the event of non observance of the safety instructions Non observance of the safety instructions can result in risk of injury to pe...

Page 5: ...ust be operated submerged without cooling jacket submerged or on the surface with cooling jacket DANGER Mortal danger through electric shock The pump must not be used for draining swim ming pools gard...

Page 6: ...te See name plate Max delivery head See name plate Operating mode S1 1 Without cooling jacket Motor submerged With cooling jacket Motor on surface Operating mode intermittent duty S3 2 Motor on surfac...

Page 7: ...General The installation site for the pump must be free of frost The shaft must be cleared of coarse material such as rubble before setting up and starting the pump Thepressurepipemusthavethenominaldi...

Page 8: ...mains Connect the pump 7 2 1 Pump with single phase motor 1 230 V The motor is already wired withthe condenser box at the works The mains connection is made at terminals L1 N PE of the terminal box A...

Page 9: ...level must not drop below the permit ted minimum switch off level See the installation and operating instructions for the level control device The switch off point must be chosen so that the operating...

Page 10: ...ow rate according to the follow ing formula With the horizontal section A the following gen eral formula can be used Q m h 36 x A m2 x h cm t s 9 3 Oil change WARNING Risk of injury The pumps are heav...

Page 11: ...voltage Check the wires and fuses or switch auto matic fuses in the distribution station back on Rotor blocked Clean the housing and impeller if still blocked replace the pump Fuses condenser defectiv...

Page 12: ...jectives of the low voltage directive 2006j95jEC are realized according annex I No 1 5 1 of the EC Machinery directive 2006j42jEC Les objectifs protection de la directive basse tension 2006j95jEC sont...

Page 13: ...strojn za zen 98 37 ES bzw 2006 42 ES dyrektyw maszynow WE 98 37 WE bzw 2006 42 WE EC 98 37 EG bzw 2006 42 EG C le t kaj c se bezpe nosti stanoven ve sm rnici o elektrick ch za zen ch n zk ho nap t js...

Page 14: ...lint Budapest T 36 23 889500 wilo wilo hu Ireland WILO Engineering Ltd Limerick T 353 61 227566 sales wilo ie Italy WILO Italia s r l 20068 Peschiera Borromeo Milano T 39 25538351 wilo italia wilo it...

Page 15: ...263 Dortmund T 0231 4102 7900 T 01805 W I L O K D 9 4 5 6 5 3 F 0231 4102 7126 Erreichbar Mo Fr von 7 17 Uhr Wochenende und feiertags 9 14 Uhr elektronische Bereitschaft mit R ckruf Garantie Kundendie...

Reviews: