English
20
WILO SE 07/2013
NOTE:
The axial deviation of the two coupling halves may be a max. of
0.1 mm in every state, i.e. even at the operating temperature and
when inlet pressure is applied.
• When correctly aligned, connect the coupling halves and mount the
coupling protection. The tightening torques of the coupling are listed
in Tab. 6.
Tightening torques for set screws and coupling halves
(see also Fig. 15 and Fig. 16 ):
Tab. 6: Tightening torque for set screws and coupling halves
7.5.3
Alignment of the pump unit
All deviations in the measuring results indicate a misalignment. In this
case, the unit must be realigned to the motor.
• To do this, loosen the hexagon head bolts and the counter nuts on the
motor.
• Place shims under the motor feet until the height difference is com-
pensated. Pay attention to the axial alignment of the coupling.
• Tighten the hexagon head bolts again.
• Finally, check the function of the coupling and shaft. The coupling
and shaft must be easy to turn by hand.
• After correct alignment, mount the coupling protection.
Fig. 14: Checking the axial alignment with a
calliper gauge - circumferential check
Fig. 15: Set screw A for axial safeguard
Fig. 16: Fastening screws B of coupling
halves
A
B
B
Coupling
parameter d
[mm]
Tightening torque,
set screw A
[Nm]
Tightening torque,
set screw B
[Nm]
80, 88, 95, 103
4
13
110, 118
4
14
125, 135
8
17.5
140, 152
8
29
160, 172
15
35
180, 194
25
44
200, 218
25
67.5
225, 245
25
86
250, 272
70
145
280, 315
70
185
350, 380
130
200
400, 430
130
340
440, 472
230 410