Technical data
Please state all the information on the pump name plate when order-
ing spare parts.
Fluids
If water/glycol mixtures with up to 40% glycol (or fluids with viscosi-
ties different from pure water) are used, the pump data must be cor-
rected accordingly (depending on the percentage mixture ratio and
fluid temperature). The motor power must also be adjusted if neces-
sary.
• Only use mixtures with corrosion inhibitors. The respective manufac-
turer's instructions are to be observed.
• The fluid must be free of sediments.
• Wilo's approval must be obtained for use of other media.
• Mixtures with a proportion of glycol of > 10% influence the
Δ
p-v
pump curve and the flow calculation.
NOTE:
The safety data sheet of the pumped fluid must always be observed!
Property
Value
Remarks
Nominal speed
2900, 1450, 960 rpm
Nominal diameters, DN
NL: 32 - 150
NLG: 150 - 300
Permissible min./max. fluid temperature
NL:
-20 °C to +120 °C
NLG: -20 °C to +120 °C
Design with seal ring classifi-
cation
Permissible min./max. fluid temperature
NL:
-20 °C to +105 °C
NLG: -20 °C to +105 °C
Design with stuffing box
packing
Max. ambient temperature
+ 40 °C
Max. permissible operating pressure
16 bar
Insulation class
F
Protection class
IP 55
Flanges
NL:
PN 16 in acc. with DIN EN 1092-2
NLG: PN 16 in acc. with ISO 7005-2
Approved fluids
• Heating water according to VDI 2035
• Cooling/cold water
• Water/glycol mixture up to 40% vol.
• Heat transfer oil
• Other fluids (on request)
• Standard version
• Standard version
• Standard version
• Special version or auxiliary
equipment (at additional
charge)
• Special version or auxiliary
equipment (at additional
charge)
Electrical connection
3~400 V, 50 Hz
Standard version
Special voltages/frequencies
Pumps with motors with different volt-
ages or with other frequencies are avail-
able on request.
Special version or auxiliary
equipment (at additional
charge)
Motor protection
PTC thermistor sensor
Tab. 1: Technical data