INSTALLATION 

Figure 6 - Removing  Lower Front  

Panel  Of  Heater 

Figure    4  -Mounting    Clearances 

As  Viewed  From  Front  Of Heater

FASTENING  HEATER  TO  WALL  

Mounting  Bracket  

The    mounting    bracket    is    located        
on      back    panel    of    heater  (see              
Figure 5).  It  has  been  taped  there   
for  shipping.  Remove  mounting 
bracket  from  back  panel.  

Removing Lower Front Panel Of 

Heater  

1.   Remove   two   screws   near
      bottom  corners  of  lower front
      panel.  
2.   Pull  bottom of  lower front  panel  
      forward, then  down  (see  Figure 
      6).  

Methods For Attaching  Mounting  

Bracket  To Wall  

Only  use  last  hole  on  each  end        
of    mounting    bracket    to    attach    
bracket   to  wall.  Attach  mounting              
bracket to wall only in one of  two ways:  
1.    Attaching  to  wall  stud  
2.    Attaching  to  wall  anchor 

Attaching  to  Wall  Stud:

 This  method  

provides  the  strongest  hold.  Insert  
mounting    screws    through    mount-
ing    bracket    and    into    wall    studs. 

 

Attaching    to    Wall   Anchor:

  This 

method    allows    you    to  attach        
mounting    bracket    to    hollow    walls 
(wall  areas  between    studs)  or  to 
solid   walls  (concrete  or  masonry).   
Decide      which      method      better          
suits    your    needs.    Either    method        
will  provide  a  secure   hold  for  the 
mounting  bracket.  

Marking  Screw  Locations  

1.  Tape  mounting  bracket  to  wall 
where    heater    will    be    located.         
Make    sure    mounting    bracket    is 
level.  

2.    Mark    screw    locations    on             
wall. (see  Figure  7)  

Note:

    Only    mark    last    hole    on         

each    end    of    mounting    bracket.          
Insert    mounting    screws    through
these  holes  only. 
3.      Remove    tape  and    mounting 
bracket  from  wall.  
 

Figure 7 - Mounting  Bracket  

Clearances

          WARNING:      

Maintain     

minimum   clearances  shown  in 
Figure  8.  If    you    can,    provide 
greater   clearances   from   floor
and   joining   wall.   

   Figure  5 -Mounting Bracket

                    Location

  WARNING: 

Maintain  the 

minimum  clearances    shown 
i n     F i g u r e   4 .   I f   y o u   c a n ,  
provide  greater  clearances  from  
floor, ceiling, and joining wall.

Summary of Contents for 2696541

Page 1: ...qualified installer service agency or gas supplier F I T R I I D S E E C GN D E R Table of Contents Important Safety Information 2 Product Features 3 Proper Ventilation Fresh Air 4 Installation 6 Oper...

Page 2: ...un heater with control knob at LOW or HIGH locked positions Never set control knob between locked positions Poor combustion and higher levels of carbon monox ide may result 5 This heater needs fresh o...

Page 3: ...1 Remove heater from carton 2 Remove all protective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater...

Page 4: ...Length Width Height cu ft volume of space Example Space size18ft length 16ft width 8ft ceiling height 23040cu ft volume of space If additional ventilation to adjoining room is supplied with grills or...

Page 5: ...Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount...

Page 6: ...Installing heater next to vinyl or cloth wall cover ings or operating heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may dis...

Page 7: ...sert mounting screws through mount ing bracket and into wall studs Attaching to Wall Anchor This method allows you to attach mounting bracket to hollow walls wall areas between studs or to solid walls...

Page 8: ...aching Mounting Bracket To Wall Note Wall anchors mounting screws and spacers are in hardware package The hardware package is provided with heater Attaching to Wall Stud Method For attaching mounting...

Page 9: ...o not reduce incoming gas pressure heater regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 12 Pointing the vent down protects it from freezing rai...

Page 10: ...n main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 15 Apply mixture of...

Page 11: ...e Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position Do not operate between locked positions TO TURN OFF GAS TO APPLIANCE Shutting...

Page 12: ...re 23 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 23 Pilot Air Inlet Hole CABINET Air Passageways Use...

Page 13: ...in 2 Control knob is not pressed in long enough 3 Equipment shutoff valve is not fully open 4 Thermocouple connection is loose at control valve 5 Pilot flame is not touching thermocouple This allows...

Page 14: ...cked positions 1 Residues from manufacturing processes 1 Metal is expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into...

Page 15: ...any 3 Clean ODS pilot see Cleaning page 12 1 Locate and correct all leak s see Checking Gas Connections page 10 2 Contact Dealer or Williams Furnace 1 Take apart gas tubing and remove foreign matter 2...

Page 16: ...ed propane LP or natural gas purchase date warranty card Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they...

Page 17: ...17 ILLUSTRATED PARTS BREAKDOWN 2696541 ODS Pilot Assembly Burner Assembly...

Page 18: ...mbly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple lgnitor Electrode ODS Mounting Bracket Self Tapping Screw Control Valve Ignitor Line Control Valve Bracke...

Page 19: ...voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERED This warranty does not apply t...

Reviews: