INSTALLATION 

CONNECTING TO GAS SUPPLY  

              WARNING:   

A    qualified        

service    person    must    connect 
heater  to  gas  supply. Follow  all  
local  codes.  

 

WARNING

:  Do  not  over

t i g h t e n   g a s   c o n n e c t i o n s .

           WARNING:  

This  appliance 

requires    a    3/8

    NPT    (National 

Pipe    Thread)    inlet    connection 
to  the  pressure  regulator.  

                    CAUTION:   

Never    con-

nect  heater    private  (non-utility)  
gas well. This  gas  is  commonly  
known as  well-head  gas.  

*A  CSA/AGA    design-certified    equipment    shutoff    valve    with    1/8

    NPT  

tap  is  an   acceptable   alternative  to  test  gauge   connection.  Purchase 
the    optional    CSA/AGA    design-certified    equipment    shutoff    valve    from 
your  dealer.  See  Accessories,  page 17.  

  CAUTION:   

Use   pipe   joint 

sealant    that    is    resistant    to      
propane gas.  

Figure 13 -Gas  Connection

  CAUTION:   

Use    only    new, 

black iron or steel pipe. Internally-

tinned copper tubing  may be used  

in certain areas. Check your local 

codes. Use pipe  of  large  enough 

diameter  to  allow  proper  gas  vol-

ume  to heater. If pipe is too small,                       

undue  loss  of pressure will occur. 

The installer must supply an external 
regulator. The external regulator will 
reduce incoming gas pressure. You 
must reduce incoming gas pressure 
to between 11 and 14 inches of wa-
ter. If you do not reduce incoming gas
pressure, heater regulator damage
could occur. Install external regulator 
with the vent pointing down as shown 
in Figure 12. Pointing the vent down 
protects it from freezing rain or sleet.

Figure 12 - External Regulator with

Vent Pointing Down

Typical Inlet Pipe Diameters
All models up to 20,000 BTU’s use
3/8’’ or greater pipe; 
All models 25,000 BTU’s and higher, 
use 1/2” or greater pipe.
Installation must include an
equipment shutoff valve, union,
and plugged 1/8" NPT tap. Locate
NPT tap within reach for test gauge
hook up. NPT tap must be upstream 
from heater (see Figure 13).

IMPORTANT

: Install an equipment

shutoff valve in an accessible
location. The equipment shutoff
valve is for turning on or shutting
off the gas to the appliance.

Apply pipe joint sealant lightly to
male threads. This will prevent
excess sealant from going into
pipe. Excess sealant in pipe could
result in clogged heater valves.

Install sediment trap in supply line
as shown in Figure 13. Locate sedi-
ment trap where it is within reach for 
cleaning. Locate sediment trap where 
trapped matter is not likely to freeze. 
A sediment trap traps moisture and
contaminants. This keeps them from 
going into heater controls. If sediment 
trap is not installed or is installed 
wrong, heater may not run properly.

IMPORTANT

: Hold pressure

regulator with wrench when
connecting it to gas piping and/or
fittings.

Summary of Contents for 2696541

Page 1: ...qualified installer service agency or gas supplier F I T R I I D S E E C GN D E R Table of Contents Important Safety Information 2 Product Features 3 Proper Ventilation Fresh Air 4 Installation 6 Oper...

Page 2: ...un heater with control knob at LOW or HIGH locked positions Never set control knob between locked positions Poor combustion and higher levels of carbon monox ide may result 5 This heater needs fresh o...

Page 3: ...1 Remove heater from carton 2 Remove all protective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater...

Page 4: ...Length Width Height cu ft volume of space Example Space size18ft length 16ft width 8ft ceiling height 23040cu ft volume of space If additional ventilation to adjoining room is supplied with grills or...

Page 5: ...Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount...

Page 6: ...Installing heater next to vinyl or cloth wall cover ings or operating heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may dis...

Page 7: ...sert mounting screws through mount ing bracket and into wall studs Attaching to Wall Anchor This method allows you to attach mounting bracket to hollow walls wall areas between studs or to solid walls...

Page 8: ...aching Mounting Bracket To Wall Note Wall anchors mounting screws and spacers are in hardware package The hardware package is provided with heater Attaching to Wall Stud Method For attaching mounting...

Page 9: ...o not reduce incoming gas pressure heater regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 12 Pointing the vent down protects it from freezing rai...

Page 10: ...n main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 15 Apply mixture of...

Page 11: ...e Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position Do not operate between locked positions TO TURN OFF GAS TO APPLIANCE Shutting...

Page 12: ...re 23 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 23 Pilot Air Inlet Hole CABINET Air Passageways Use...

Page 13: ...in 2 Control knob is not pressed in long enough 3 Equipment shutoff valve is not fully open 4 Thermocouple connection is loose at control valve 5 Pilot flame is not touching thermocouple This allows...

Page 14: ...cked positions 1 Residues from manufacturing processes 1 Metal is expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into...

Page 15: ...any 3 Clean ODS pilot see Cleaning page 12 1 Locate and correct all leak s see Checking Gas Connections page 10 2 Contact Dealer or Williams Furnace 1 Take apart gas tubing and remove foreign matter 2...

Page 16: ...ed propane LP or natural gas purchase date warranty card Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they...

Page 17: ...17 ILLUSTRATED PARTS BREAKDOWN 2696541 ODS Pilot Assembly Burner Assembly...

Page 18: ...mbly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple lgnitor Electrode ODS Mounting Bracket Self Tapping Screw Control Valve Ignitor Line Control Valve Bracke...

Page 19: ...voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERED This warranty does not apply t...

Reviews: