SPECIFICATIONS

Btu(available)
Gas Type
Ignition
Pressure Regulator setting
Inlet Gas Pressure* (inches of water)
Maximum
Minimum
Dimensions, Inches (HxWxD)
Heater
Carton
Weight (pounds)
Heater
Shipping

Note: 

 Dimensions  listed  are  outer  most  points  on  the  heater  (includes  control  knobs  and  grill).

* For purposes of input adjustment.

2696541

6,000/15,000/25,000

Propane/LP  Only

Piezo

10

 W.C.

14

11

23 1/2 × 26 5/8 × 8

25 3/4 × 28 1/2 × 9 1/4

30
35

REPLACEMENT  PARTS

Note: 

 Use  only  original  replacement 

parts. This  will  protect  your  warranty 

coverage   for   parts   replaced   under 

warranty.

PARTS UNDER WARRANTY

Contact    authorized      dealer    from  

whom  you  purchased  this  product.   

If  they  are  unable  to  supply  original 

replacement  part(s),  call  the  number 

on  the  front  of  this manual.  When  

contacting  your  dealer or  Williams 

Furnace, have ready:

 

your  name

 

your  address

 

model     and    serial    numbers   of 

       your  heater

 

how  heater  was  malfunctioning

 

type of  gas   used  (propane/LP or  

       natural  gas)

 

purchase  date

 

warranty card

Usually,  we  will ask you to return the 

defective  part  to  the  factory.

PARTS NOT UNDER

WARRANTY

Contact  authorized  dealers  of  this 

product.  If  they  can’t  supply  original 

replacement part(s),  contact Williams 
Furnace at 

(909)825-0993

.

ACCESSORIES

Purchase   these   heater  accessories from   
your   local  dealer.   If   they  can not sup-
ply   these  accessories,  contact  Williams 
Furnace  for information. You   can   also   
write   to   the  address listed  on the front  
of this  manual.

EQUIPMENT  SHUTOFF  VALVE

For    all    models.  Equipment    shutoff 
valve  with  1/8

” 

 NPT  tap.

FLOOR  MOUNTING  STAND

For    locating    heater    on    the    floor  
away  from  a  wall.  Complete installa-
tion  instructions  provided  with  floor  
mounting  stand.

TECHNICAL SERVICE

You      may      have    further    ques-
tions  about    installation,    operation,  
or  troubleshooting.    If  so,    contact        
Williams Furnace at 

(909)825-0993

.

Optional FAN Kit - 2295
The optional fan kit fits all models noted 
in this manual. The fan has 3 settings 
ON/OFF/Auto. The thermostatically 
controlled fan improves heater ef-
ficiency and includes installation and 
operating instructions.

FAN KIT

Summary of Contents for 2696541

Page 1: ...qualified installer service agency or gas supplier F I T R I I D S E E C GN D E R Table of Contents Important Safety Information 2 Product Features 3 Proper Ventilation Fresh Air 4 Installation 6 Oper...

Page 2: ...un heater with control knob at LOW or HIGH locked positions Never set control knob between locked positions Poor combustion and higher levels of carbon monox ide may result 5 This heater needs fresh o...

Page 3: ...1 Remove heater from carton 2 Remove all protective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater...

Page 4: ...Length Width Height cu ft volume of space Example Space size18ft length 16ft width 8ft ceiling height 23040cu ft volume of space If additional ventilation to adjoining room is supplied with grills or...

Page 5: ...Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount...

Page 6: ...Installing heater next to vinyl or cloth wall cover ings or operating heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may dis...

Page 7: ...sert mounting screws through mount ing bracket and into wall studs Attaching to Wall Anchor This method allows you to attach mounting bracket to hollow walls wall areas between studs or to solid walls...

Page 8: ...aching Mounting Bracket To Wall Note Wall anchors mounting screws and spacers are in hardware package The hardware package is provided with heater Attaching to Wall Stud Method For attaching mounting...

Page 9: ...o not reduce incoming gas pressure heater regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 12 Pointing the vent down protects it from freezing rai...

Page 10: ...n main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 15 Apply mixture of...

Page 11: ...e Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position Do not operate between locked positions TO TURN OFF GAS TO APPLIANCE Shutting...

Page 12: ...re 23 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 23 Pilot Air Inlet Hole CABINET Air Passageways Use...

Page 13: ...in 2 Control knob is not pressed in long enough 3 Equipment shutoff valve is not fully open 4 Thermocouple connection is loose at control valve 5 Pilot flame is not touching thermocouple This allows...

Page 14: ...cked positions 1 Residues from manufacturing processes 1 Metal is expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into...

Page 15: ...any 3 Clean ODS pilot see Cleaning page 12 1 Locate and correct all leak s see Checking Gas Connections page 10 2 Contact Dealer or Williams Furnace 1 Take apart gas tubing and remove foreign matter 2...

Page 16: ...ed propane LP or natural gas purchase date warranty card Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they...

Page 17: ...17 ILLUSTRATED PARTS BREAKDOWN 2696541 ODS Pilot Assembly Burner Assembly...

Page 18: ...mbly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple lgnitor Electrode ODS Mounting Bracket Self Tapping Screw Control Valve Ignitor Line Control Valve Bracke...

Page 19: ...voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERED This warranty does not apply t...

Reviews: