Williams 2696541 Owner'S Operation And Installation Manual Download Page 18

18

PARTS  LIST
2696541

This  list  contains  replaceable  parts  for  your  heater.  When  ordering  replacement parts, 
follow   the  instructions  listed under  Replacement  Parts  on  page 16  of  this  manual.

KEY 
NO.

1
2
3
4
5

5-1
5-2

6
7
8
9

10

11

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

 PART 
NUMBER
MB10051
MB09051
MB11051
MB19002
ND1808x400x9
ND0803-4
ND0807
ML026-01
ML069-02
NV2020-14
ML073-01
ML028-01
ML029-01
ML030-01
MB40001
MB40002
MB40003
MB40012
MB40013
MB40004
MB40014
MB40015
MB40005
ML090-02
ML056-01
MB16001
MB16003
NRV81FIL-10
96-4Z
ML079-01
MB29001W
ML083-03
MB060-01
ML105-01

MB28001
ML070-06W
ML071-02
ML072-01

DESCRIPTION
Cabinet Assembly
Lower Front Panel Assembly
Reflector Unit
Burner Assembly
ODS Pilot Assembly
Thermocouple
lgnitor Electrode
ODS Mounting Bracket
Self Tapping Screw
Control Valve
Ignitor Line
Control Valve Bracket
Control Valve Fixed Nut
Control valve main inlet nut
Main Inlet Tube Assembly
ODS Gas Line Assembly
Burner Gas Line Assembly C
Burner Gas Line Assembly C1
Burner Gas Line Assembly C2
Burner Gas Line Assembly B
Burner Gas Line Assembly B1
Burner Gas Line Assembly B2
Burner Gas Line Assembly A
Injector
“T” Joint
Control Knob Assembly
Control Rod Assembly
Pressure Regulator
Washer
Self Locking Screw
Grill Guard
Ignitor Assembly
Mounting Bracket Assembly
ODS Upper Deflector

Assembly  Hardware
CSA/AGA   Label
Gas Instruction Decal
Inside Warning Label

QTY

1
1
1
1
1
1
1
1

14

1
1
1
1
1
1
1
1
1
1
1
1
1
1
5
2
1
1
1
2
2
1
1
1
1

1
1
1
1

PARTS  AVAILABLE  NOT SHOWN  

Summary of Contents for 2696541

Page 1: ...qualified installer service agency or gas supplier F I T R I I D S E E C GN D E R Table of Contents Important Safety Information 2 Product Features 3 Proper Ventilation Fresh Air 4 Installation 6 Oper...

Page 2: ...un heater with control knob at LOW or HIGH locked positions Never set control knob between locked positions Poor combustion and higher levels of carbon monox ide may result 5 This heater needs fresh o...

Page 3: ...1 Remove heater from carton 2 Remove all protective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater...

Page 4: ...Length Width Height cu ft volume of space Example Space size18ft length 16ft width 8ft ceiling height 23040cu ft volume of space If additional ventilation to adjoining room is supplied with grills or...

Page 5: ...Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount...

Page 6: ...Installing heater next to vinyl or cloth wall cover ings or operating heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may dis...

Page 7: ...sert mounting screws through mount ing bracket and into wall studs Attaching to Wall Anchor This method allows you to attach mounting bracket to hollow walls wall areas between studs or to solid walls...

Page 8: ...aching Mounting Bracket To Wall Note Wall anchors mounting screws and spacers are in hardware package The hardware package is provided with heater Attaching to Wall Stud Method For attaching mounting...

Page 9: ...o not reduce incoming gas pressure heater regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 12 Pointing the vent down protects it from freezing rai...

Page 10: ...n main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 15 Apply mixture of...

Page 11: ...e Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position Do not operate between locked positions TO TURN OFF GAS TO APPLIANCE Shutting...

Page 12: ...re 23 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 23 Pilot Air Inlet Hole CABINET Air Passageways Use...

Page 13: ...in 2 Control knob is not pressed in long enough 3 Equipment shutoff valve is not fully open 4 Thermocouple connection is loose at control valve 5 Pilot flame is not touching thermocouple This allows...

Page 14: ...cked positions 1 Residues from manufacturing processes 1 Metal is expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into...

Page 15: ...any 3 Clean ODS pilot see Cleaning page 12 1 Locate and correct all leak s see Checking Gas Connections page 10 2 Contact Dealer or Williams Furnace 1 Take apart gas tubing and remove foreign matter 2...

Page 16: ...ed propane LP or natural gas purchase date warranty card Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they...

Page 17: ...17 ILLUSTRATED PARTS BREAKDOWN 2696541 ODS Pilot Assembly Burner Assembly...

Page 18: ...mbly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple lgnitor Electrode ODS Mounting Bracket Self Tapping Screw Control Valve Ignitor Line Control Valve Bracke...

Page 19: ...voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERED This warranty does not apply t...

Reviews: