PAGE 66 OF 98
NIGHT SCAN POWERLITE, POWERLITE XTREME, AND POWERLITE HDT
OPERATING INSTRUCTIONS
TP-4723701-U
MAY 2021
8.3 D-TEC® Sensor
The D-TEC® Sensor is an optional accessory that is mounted on the backside of the RCP to
detect and prevent operation near power lines. The D-TEC® Sensor senses electric field
strength and prevents the mast from raising if the field strength is above the alarm threshold.
8.3.1
D-TEC® Sensor Location
When using the D-TEC® Sensor with a Will-Burt RCP, the unit will be mounted on the side of the
RCP cover plate opposite of the RCP circuit board. This typically is installed by The Will-Burt
Company. The Sensor unit must be mounted in the upright position with the look-up light pointing
up.
Figure 8-2 D-TEC® Sensor Installed on RCP
The cable used to connect the Sensor unit to the RCP should be connected to the bottom of the
Sensor unit and wired into the RCP PC board as shown.
Figure 8-3 D-TEC® Wiring Schematic
Look-up Light
D-TEC® Sensor
D-TEC® Cable