PAGE 17 OF 98
NIGHT SCAN POWERLITE, POWERLITE XTREME, AND POWERLITE HDT
OPERATING INSTRUCTIONS
TP-4723701-U
MAY 2021
3.2 Mast Position Definition
An actuator electrically tilts the mast from the stowed position to the 90° position. The mast is
then pneumatically moved by air pressure to the extended position. The following positions (see
Figure 3-2) are used throughout this manual:
•
Stowed:
is the horizontal position in which the mast is firmly seated in the saddle. This
position is sometimes referred to as the nested position.
•
90°:
is the position that the mast electrically goes to from the stowed position. At 90°, the
mast has angled up, but no mast sections have risen. The mast remains retracted.
•
Extended:
is the partial or full raised position that the mast pneumatically goes after the 90°
position. In the extended position, some or all of the mast sections have risen.
Figure 3-2 Mast Positions