PAGE 32 OF 98
NIGHT SCAN POWERLITE, POWERLITE XTREME, AND POWERLITE HDT
OPERATING INSTRUCTIONS
TP-4723701-U
MAY 2021
Note: The exact dimensions of your system will vary based on the components included.
Additional room may be required for additional components, such as optional cameras or strobe
lights.
5.5 Attaching the Air Connections
Two barbed fittings are provided for connecting the air-lines required to pressurize and exhaust
the system (see Figure 5-4). Air may be supplied externally by a compressor or other source of
clean, dry air with a maximum pressure of 100 psi (6.9 bar). Your system has an internal
regulator factory set to 20 psi (1.4 bar). The inlet fitting is to be used with a 3/8 inch (or equivalent
metric) inside diameter air hose rated for the pressure supplied in combination with
environmental factors, which may derate the hose (e.g. high temperatures). The unit is supplied
with 20 feet (6m) of air hose labeled SUPPLY to designate the pressurized air to be routed to the
INLET of the unit. The exhaust fitting is to be used with a ½ inch (or equivalent metric) inside
diameter air hose. The unit is supplied with 20 feet (6 m) of air hose labeled EXHAUST to
designate its use to route exhausted air to a location where it will not expel air or water onto
personnel or equipment sensitive to moisture. The different size hose with the labeled intention of
the hose is designed to prevent pressurized air to be routed into the EXHAUST of the unit. If
pressurized air is routed into the EXHAUST port of the mast, the unit is equipped with a blow-off
valve that will prevent this pressurized air from entering the mast. An audible air leak will be
evident to alert you that air has been improperly connected to the unit.
Table 5-3 Installation Dimensions
Model
Dimension A Value (from Figure 5-3)
Powerlite 2.3
46.190 inches [1173.2 mm]
Powerlite 3.0
54.531 inches [1385 mm]
Powerlite 4.5
66.573 inches [1691 mm]
Powerlite Xtreme 6.0
83.231 inches [2114 mm]
Powerlite Xtreme 7.5
94.231 inches [2393.5 mm]
Summary of Contents for Night Scan Powerlite