8
900 STANDARD MANTEL
CRITICAL DIMENSIONS
This Mantel MUST be constructed from Non-Combusble Materials.
These diagrams detail the CRITICAL dimensions which must be achieved for correct installaon
of the appliance when being installed into a
900 STANDARD MANTEL.
.
NOTE:
Front Lower Marble Access Plate Dimensions and installaon for BOTH
900 STANDARD
&
900 PRECAST
MANTELS
is detailed separately on page 10
DESCRIPTION
mm
(min)
mm
(max)
A
Width of Opening
662mm
664mm
B
Height of Opening
744mm
747mm
C
Height of Hearth
50mm
N/A
D
Width of Hearth
960mm
N/A
E
Depth of Hearth
381mm
N/A
F
Effecve Rebate to Front Marble Face
164mm
167mm
G
FIXING PLATE (Width) Area to be kept clear within Mantel
780mm
N/A
H
FIXING PLATE Area (Depth) to be kept clear within Mantel
140mm
N/A
J
FIXING PLATE Area (Height) to be kept clear within Mantel
800mm
N/A