background image

INSTALLATION TYPE C 

These diagrams detail the installaon of the appliance into a Pre Cast Flue where a 

900 PRECAST MANTEL

 is being fied 

For details on 

900 PRECAST MANTEL 

crical dimensions see page 9. 

The 

900  PRECAST  SPACER  KIT 

is  used  to  create  an 

interface  between  the  precast  flue  and  the 

900  FIXING 

PLATE

.  Fit  the  hearth  and  firmly  aach  the  PRECAST 

SPACER to the wall.  See further details on page 12. 

 

Using  mortar  or  fondue  around  the  inside  edge  of  the 

SPACER/FLUE should be sealed and fixed into place as if it 

were a marble back panel. It is important that no leakage 

should occur. 

 

 

For minimum hearth requirements see page 9. 

 

The 

900  FIXING  PLATE 

is  then  screwed  to  the  900 

PRECAST  SPACER  with  the  screws  provided.  Using  fire 

cement  or  similar  around  the  inside  edge  of  the  joint 

between  the 

900  FIXING  PLATE 

and  the 

900  PRECAST 

SPACER

. Furthermore a suitable high temperature masc 

should be used to further seal around the outside edge of 

the 

900  FIXING  PLATE 

and the wall.  See further details 

on page 13 

 

It  is  extremely  important  that  both  the 

900  PRECAST 

SPACER 

and the 

900 FIXING PLATE 

are sealed to the flue 

as  essenally  a  complete  fireplace  opening.  Check  the 

integrity of the spacer and fixing plate installaon before 

proceeding. 

 

The TYPE C INSTALLATION is completed by installing  the 

900    PRECAST  MANTEL 

to the wall securely. The mantel 

should be centred around the 

900 FIXING PLATE

 

The crical dimensions of the 

900 PRECAST MANTEL 

are 

detailed on page 9. These crical dimensions ensure that 

the front trim plate of the fire and the front face of the 

mantel are aligned. 

 

The  front  trim  plate  of  the  appliance  is  fully  adjustable 

with  four  independent  magnets.  These  magnets  can  be 

screwed  in  or  out  to  posion  the  front  trim  plate 

correctly.  This  adjustment  is  provided  as  there  may  be 

some variaon in the wall flatness and level. 

 

See  page  17  for  full  details  regarding  front  trim 

installaon and adjustment. 

 

 

 

Ensure the hearth is set level before connuing with 

the installaon. Failure to install a level hearth could  

affect the installaon of the mantel and appliance. 

Summary of Contents for HE900

Page 1: ...r is able to fully operate the appliance and is aware of any cleaning or maintenance requirements HE900 GAS FIRE Model number F 081XX2 for use on Natural Gas G20 at a supply pressure of 20 mbar in GB...

Page 2: ...nstalla ons 13 Installa on of Fixing Plate Standard Installa ons 14 Installing the Mantel 15 Installing the Appliance 16 Connec ng the Appliance to the Gas Supply 16 Glass Panel Front Trim Installa on...

Page 3: ...to this appliance and must have no openings to any other room The opening should be inspected and any exposed brickwork should be repaired where necessary The chair brick if applicable should be remov...

Page 4: ...stalla on then no hearth is technically required however the installer should make the customer aware of the recommenda ons detailed on page 16 Do not place so wall coverings i e embossed papers etc f...

Page 5: ...igh temperature mas c should be used to further seal around the outside edge of the 900 FIXING PLATE and the wall The TYPE A INSTALLATION is completed by installing the 900 STANDARD MANTEL to the wall...

Page 6: ...900 PRECAST SPACER using the screws provided then using re cement or similar around the inside edge of the joint between the 900 FIXING PLATE and the 900 PRECAST SPACER Furthermore a suitable high te...

Page 7: ...edge of the 900 FIXING PLATE and the wall See further details on page 13 It is extremely important that both the 900 PRECAST SPACER and the 900 FIXING PLATE are sealed to the ue as essen ally a comple...

Page 8: ...installa on for BOTH 900 STANDARD 900 PRECAST MANTELS is detailed separately on page 10 DESCRIPTION mm min mm max A Width of Opening 662mm 664mm B Height of Opening 744mm 747mm C Height of Hearth 50m...

Page 9: ...installa on for BOTH 900 STANDARD 900 PRECAST MANTELS is detailed separately on page 10 DESCRIPTION mm min mm max A Width of Opening 662mm 664mm B Height of Opening 744mm 747mm C Height of Hearth 50mm...

Page 10: ...ntrols area of the appliance and provides access for ba ery changes or service The installer should check that the Access Cover has been made to the correct dimensions and then ensure the rear face is...

Page 11: ...and aligned installa on of the appliance The minimum hearth dimensions are shown in the diagrams on pages 8 and 9 The upper surface of the hearth must be a minimum of 50mm above the oor and the repla...

Page 12: ...S FIXING PLATE IS INSTALLED BEFORE THE MANTEL AND FIRE ARE FITTED When the hearth has been installed and the replace opening is prepared as per the details on page 11 of these instruc ons the PRECAST...

Page 13: ...RECAST INSTALLATIONS ONLY For Class 1 and Class 2 installa ons see page 14 PRECAST INSTALLATIONS Once screwed into posi on ensure this FIXING PLATE is sealed air ght against the PRECAST SPACER with a...

Page 14: ...the wall symmetrically around the replace opening and hearth Use the 7 screws and plugs supplied in the appliance installa on kit Once screwed into posi on ensure this FIXING PLATE is sealed air ght...

Page 15: ...tended for installa on into a marble or stone mantel constructed of non combus ble material For this reason no clearances from combus ble shelf are given INSTALLING THE MANTEL ALL INSTALLATIONS Instal...

Page 16: ...Fit the slide lever to the burner tray using the 2 two screws provided Carefully slide the rebox into the opening Note the rubber seal is pre ed to the appliance on the sealing face THIS APPLIANCE CAN...

Page 17: ...arble access cover ensuring the control lever pokes through the lower slot in the trim Now rotate into posi on The front face of the trim should be in line with the front of the mantel and access cove...

Page 18: ...o the centre slot at the top of the appliance Once fully in the holder should be rotated 90 degrees Now move the match holder to the le side of the slot AS FAR AS POSSIBLE This will posi on the smoke...

Page 19: ...arch used in the manufacturing of the ceramic fuel bed paints curing and oils remaining on some metal components that will burn o This odour is non toxic and will eventually disappear a er a few hours...

Page 20: ...emove any dust or deposits If you intend to use a vacuum cleaner then this should only be done once the loose Rockwool and any loose deposits of soot etc have been removed Ensure that the moulded comp...

Page 21: ...ove the glass panel as described on page 17 Remove the fuel e ect components put in a suitable loca on where they cannot be damaged Disconnect the gas supply from the restrictor elbow Remove the six 6...

Page 22: ...he HT lead from the electronic igniter unit 4 Remove the two 2 screws securing the pilot to the burner tray 5 Remove the two 2 screws securing the microswitch to the tray 6 The pilot assembly can be r...

Page 23: ...trol lever to the right to the ame symbol A stop will be felt at this posi on 5 It is also possible to adjust the control knob between the and the ame symbols to achieve mid se ngs 6 To turn the re o...

Page 24: ...correctly These instruc ons can also be followed to remove or reinstall the fuel bed a er cleaning This is a procedure that can be undertaken by the customer as required and the frequency will be dep...

Page 25: ...25 Step 4 Fit Log B onto the burner loca on brackets as shown below Step 5 Fit Central Log C onto the fuel bed as shown in the picture below...

Page 26: ...26 Step 6 Fit Log D onto the fuel bed as shown in the picture below Step 7 Fit Log E onto the fuel bed as shown in the picture below...

Page 27: ...8 Fit Log F onto the fuel bed as shown in the picture below Step 9 Fit Log G onto the fuel bed as shown in the picture below Now re t the glass panel front trim and marble access cover see page 17 for...

Page 28: ...Gas Safe Registered Installer Full details are provided in this manual Hearth Products Ltd Unit 14 Tollgate Industrial Estate Sta ord ST16 3SU Product Fiche Manufacturer Hearth Products Ltd Model No F...

Page 29: ...1H Pack of Glow Rockwool P XX1398A Glass Panel with frame assembly P XX1398B Front Black Trim Assembly Due to our policy of con nual product improvement some diagrams and small details may not be accu...

Reviews: