2.
Design and function
2.1
Functional description
Float switches work on the float principle with magnetic transmission.
A reed contact integrated in the guide tube
is actuated through the
magnetic field of a permanent magnet, when a preset switch point
is reached. The permanent magnet is located within a float
, which
changes its height with the level of the medium it is monitoring. The
switching status of the reed contact can be evaluated and processed by
a connected control device.
The number and arrangement of floats is dependent on the number of
the defined switch points, their contact function and also the distance
between the switch points.
Connection housing
Cable bushing
Mounting thread
Guide tube
Float stop
Float
2.2
Scope of delivery
■
Float switch
■
Operating instructions
Cross-check scope of delivery with delivery note.