EN
14235429.01 01/2018 EN/DE/FR/ES
12
WIKA operating instructions models RLS
Ensure that the sealing faces of the vessel or float switch are clean and
do not show any mechanical damage.
5.2 Mounting
■
Observe the torque values of screws specified in pipefitting work.
■
In the selection of the mounting material (sealings, screws, washers
and nuts), take the process conditions into account. The suitability
of the sealing must be specified with regard to the medium and
its vapours. In addition, ensure it has corresponding corrosion
resistance.
■
Mount the float switch either via mounting thread
or mounting
flange (not illustrated).
■
The guide tube
should not be inclined more than a maximum of
30° to the vertical.
■
If the geometry of the float does not fit through the process
connection, the float must be removed before mounting.
- For this, before removal, mark
the position of the float stops
with a waterproof pen
- Mark the mounting position of
the floats (e.g. “Up”)
- After the float switch has been
mounted, the float should be
re-attached within the inside of
the tank (pay attention to the
mounting position!).
- Float stops
must then be
re-attached at the marked
points.
■
The number of floats and also
the position of the float stops are
dependent upon the dimension
and the number of switch points.
≤ 30°
5. Commissioning, operation
Summary of Contents for RLS-1000
Page 24: ...EN 14235429 01 01 2018 EN DE FR ES 24 WIKA operating instructions models RLS...
Page 46: ...DE 14235429 01 01 2018 EN DE FR ES 46 WIKA Betriebsanleitung Typen RLS...
Page 68: ...FR 14235429 01 01 2018 EN DE FR ES 68 WIKA mode d emploi types RLS...
Page 90: ...14235429 01 01 2018 EN DE FR ES 90 WIKA operating instructions models RLS...
Page 91: ...WIKA operating instructions models RLS 14235429 01 01 2018 EN DE FR ES 91...