3. Specifications
Switching current
■
without IO-Link: max. 250 mA
■
with IO-Link:
SP1 max. 100 mA, SP2 max. 250 mA
Settling time
Analogue signal:
3 ms
Switching output:
≤ 10 ms (20 ms with IO-Link)
Load
Analogue signal 4 ... 20 mA:
≤ 0.5 kΩ
Analogue signal DC 0 ... 10 V:
> 10 kΩ
Service life
100 million switching cycles
3.4 Voltage supply
Power supply
DC 15 ... 35 V
Current consumption
Switching outputs with
■
Analogue signal 4 ... 20 mA:
70 mA
■
Analogue signal DC 0 ... 10 V: 45 mA
■
without analogue signal:
45 mA
IO-Link option causes a deviating current consumption
Total current consumption
■
without IO-Link: max. 600 mA including switching current
■
with IO-Link:
max. 450 mA including switching current