4. FLC-UFL Series description
4.2.3 Nameplate
Nameplates and labels are fitted on the FLC-UFL Series
flowmeter for identification and providing details on the
specific product as well as safety related information.
Together with the safety instructions and this manual,
it specifies how to use the product and how it is designed
and certified.
The main nameplate is fitted on the Flowbody and provides
information on mechanical design conditions as well as flow
related information such as meter factor and range.
The meter’s serial number is also provided on this nameplate.
The nameplate on the SPU provides the relevant electrical
and hazardous area approval details according to ATEX,
IECEx.
The electronic individual serial number is provided on this
nameplate. Refer to the Safety instructions for an example
of this nameplate.
4.2.4 Flowbody nameplate
The Flowbody nameplate contains information about:
■
Company name and address
■
Type of Ultrasonic flowmeter
■
Model identification
■
Flow range information
■
Pressure and temperature range
■
Mechanical design parameters (design code, design
pressure and temperature)
■
Sizing and weight
■
Serial numbers
■
Year-Month
■
Warning: Read instruction manual before operating
device.
4.2.5 SPU nameplate
The SPU nameplate contains information about:
■
Company name and address
■
Type of Ultrasonic flowmeter Electronics
■
Hazardous area approval
■
Model identification
■
SPU Serial Number
■
SPU Power Requirements
■
Year of manufacture
■
Substitution of components may impair intrinsic safety
■
Install per drawing 81500909.
4.2.6 Spare parts and accessories
Please contact Euromisure for spare parts and accessories.
1
Main Board Terminal Blocks
2
Option Board Terminal Blocks
3
Ground Screw
1
2
3
4.3 Interfaces
The FLC-UFL series flowmeter has several electrical
interfaces. This chapter describes their function, operating
parameters and intrinsic safety relevant information.
4.3.1 Ground screw
A ground screw is provided to connect the FLC-UFL series
flowmeter to ground / earth.
4.3.2 Main board - Power supply
The FLC-UFL series flowmeter requires an external
intrinsically safe power supply.
Signal
Function
PWR -
Power supply
PWR +
WARNING!
The power supply interfaces of the FLC-UFL
series flowmeter are reverse polarity protected
up to 250 mA max. Always connect via a suited
intrinsically safe isolator or barrier.
Refer to Control drawing 81500909 for detailed
information.
4.3.3 Main board - Frequency out
A frequency out / pulse output is available on the mainboard
(base configuration). The main purpose of this output is
to provide pulses proportional to the volume flowing through
the pipeline. The number of pulses per unit volume (m
3
or
cubic feet) is printed on the nameplate.
Signal
Function
D0_B
Frequency output -
D0_A
Frequency