24
Operating instructions, models F6137, F6148, F6160, F6171
ADPR1X914115.01 10/2020 EN/DE
EN
9. Specifications
Model F6148
Rated force F
nom
0 ... 150 kN to 0 ... 1,500 kN
Nominal size
NS 146
Pressure measuring instrument
(mounted)
■
Pressure gauge 23x.50.100
■
Digital pressure gauge DG-10
■
Pressure sensor (on request)
Relative linearity error d
lin
Pressure gauge
≤ ±1.0 % F
nom
Pressure sensor/digital pressure gauge
≤ ±0.5 % F
nom
Temperature effect on
the characteristic value TK
c
1 % F
nom
/10 K
the zero signal TK
0
1 % F
nom
/10 K
Limit force F
L
100 % F
nom
Breaking force F
B
> 130 % F
nom
Rated displacement s
nom
< 0.5 mm
Rated temperature range B
T, nom
-30 … +60 °C
Ingress protection per IEC/EN 60529
Pressure gauge
IP65
Pressure sensor/digital pressure gauge IP67
Case
■
Steel, galvanised
■
Stainless steel
Piston
■
Steel, galvanised
■
Stainless steel
Guard bracket
Pressure gauge
yes
Pressure sensor/digital pressure gauge optional
Mounting type
Pressure gauge
direct
Pressure sensor/digital pressure gauge direct
Option
Capillary, measuring hose for “separation without
any losses”
Electrical output
Output signal
4 … 20 mA, 2-wire
Supply voltage
DC 0 … 30 V for current output
Load
≤ (UB - 6 V)/0.024 A
Electrical connection
Circular connector M12 x 1, 4-pin
Option
Hand-held measuring instrument ViSens E3908
Fill fluid (measuring piston)
Glycerine 70 %, water 30 %
Force introduction
as full-faced as possible, min. 75 % of the piston
diameter
Weight in kg
13.5
Summary of Contents for F6137
Page 32: ...32 Operating instructions models F6137 F6148 F6160 F6171 ADPR1X914115 01 10 2020 EN DE EN ...
Page 62: ...62 Betriebsanleitung Typen F6137 F6148 F6160 F6171 ADPR1X914115 01 10 2020 EN DE DE ...