Pressure sensor CPT2500 with USB adapter CPA2500 and USBsoft 

 

 

WIKA Operating Instructions, model CPT2500 

 

2.6  Advice for calibration service 

Factory calibration certificate 

– DKD-certificate – ministerial certifications: 

If the measuring device shall have a calibration certificate you have to send it inclusive the sensor to the 
manufacturer. Just the manufacturer can check the factory settings and correct them if necessary. 
 

3  Driver Installation 

3.1  Windows 2000, Windows XP, Windows Vista

™ and Windows 7 

For installation of the device drivers a user account with an administrator-authorisation is re-
quired. If you haven’t an appropriate authorisation please consult your system administrator. 

-  Insert driver disk into the drive of your PC 

-  Start the installer 

CP210XVCPInstaller.exe

 from drive. 

-  Follow the instructions of the install wizard 

-  Plug in the USB-plug connector of the CPA2500 into the USB-connection of your PC 

-  Now the CPA2500 will be installed automatically with the actual driver. 

Now the CPA2500 is installed on your system and available for all users. 
For application with our software a new additional COM-Port is available. (quod vide chapter 6) 
 

4  Frequently asked questions (FAQ) 

4.1  How to check, whether the adapter has been installed correctly and via which 

COM-port can I approach the installed adapter?

 

Start the Device-Manager (Win XP: click start \ (settings) \ control panel \ performance and maintenance \ 
system \ 

hardware) and open the submenu “Ports (COM & LPT)” 

If the 

installation was successful, there will be the entry “

CP210X USB to UART Bridge Controller (COM 

x)

”, in which the x after the Com indicates the available COM-port (i.e. COM 4). 

Note:  The adapter will not be shown in the device manager, if it is not connected to the PC. 

If the entry is occupied by an exclamation mark or the entry is not there, then the driver has not been 
installed correctly.  

4.2  How to change the COM-port of the adapter? 

Make sure that the adapter is connected, start the Device-Manager (Win XP: click start \ (settings) \ con-
trol  panel  \  performance  and  maintenance  \  system  \ 

hardware)  and open the  submenu “Ports  (COM  & 

LPT)”. If the installation was successful, there will be the entry “

CP210X USB to UART Bridge Controller 

(COM x)

”, in which the x after the Com indicates the available COM-port (i.e. COM 4).  

Open the features of this connection by a double-

click, go to “Port Settings” and then click there the button 

“Advanced...”. 
There you can choose the preferred COM-

Port at the point “COM Port Number”. If this port is already re-

served for another (even not connected) device, an error message will appear. In principle it is possible 
that 2 devices are set on the same COM-port, but then you have to take care, that not both devices are 
connected at the same time, because this would lead to a conflict. 

4.3  Is there an automatic update function that updates the installed driver to the lat-

est version?  

The driver is not updated automatically.  

If there is already a suitable (for the operating system) driver during the installation, this driver will be used 
automatically.   

If the usage of the adapter cause problems, please make sure that the latest version of the driver for the 
adapter is used and install the latest version manually (see 6.5) if necessary.  

Summary of Contents for CPA2500

Page 1: ...berg Germany Phone 49 9372 132 9986 Fax 49 9372 132 8767 E Mail testequip wika de www wika de Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft V2 2 07 2011 Pressure sensor CPT2500 with US...

Page 2: ...y and via which COM port can I approach the installed adapter 6 4 2 How to change the COM port of the adapter 6 4 3 Is there an automatic update function that updates the installed driver to the lates...

Page 3: ...ed The ownership in the rights of the program proper shall not be obtained All rights to publica tion duplication processing and exploitation of the program shall remain with WIKA WIKA guarantees that...

Page 4: ...e a damage of your attached device is possible In such case we cannot assume any warranty The manufacturer will not assume any warranty for damages to other devices resulting by use of the interface a...

Page 5: ...is possible that the connector does not snap in the jack correctly In this case you have to hold the connector at the bend relief not at the casing Don t plug the connector wedged An accu rate attach...

Page 6: ...here will be the entry CP210X USB to UART Bridge Controller COM x in which the x after the Com indicates the available COM port i e COM 4 Note The adapter will not be shown in the device manager if it...

Page 7: ...e USB adapter is not connected Go to start settings control panel and then double click software Search for the entry CP210X USB to UART Bridge Controller and click then change remove Click yes at the...

Page 8: ...2 save file 1 3 print file Sensor functions 2 1 connect USB measuring adapter 2 2 start new recording 2 3 stop recording Data representation 3 1 create new diagram Further functions 4 1 interface conf...

Page 9: ...ter instrument register extras measurements table current status of the re cording start stop condition number of data sets and period of recording 5 3 3 Start Recording When recordings are restarted...

Page 10: ...be shown in the register Data too At a cycle time of less than 5ms 200 measured values are possible At a cycle time more or equal than 5ms 50 data sets are possible which are made up of four different...

Page 11: ...al When load automatically activated overwrite existing com ment is selectable This function overwrites the existing com ment when a new record is started 5 3 7 Extras This register permits adjustment...

Page 12: ...will be displayed Select the desired graphs and acknowledge your selection by pressing Ok The diagram will be opened System limitations maximum 2 different units mbar bar etc per diagram maximum 15 g...

Page 13: ...es 5 6 3 Zoom function If 2 units are displayed use the and symbols to select the Y axis desired Place the mouse at the beginning of the desired area hold the left mouse key move the mouse to the end...

Page 14: ...Pressure sensor CPT2500 with USB adapter CPA2500 and USBsoft WIKA Operating Instructions model CPT2500 14 6 Specification...

Page 15: ...A2500 EMC directive 2004 108 EC EN 61326 Emission Group 1 Class B and Immunity controlled electromagnetic environment This equipment is designed for operation in a controlled electromagnetic environme...

Page 16: ...en COM Port des Adapters ndern 20 4 3 Wird ein lterer bereits im System vorhandener Treiber automatisch aktualisiert 21 4 4 Wie kann ich die verwendete Treiberversion feststellen 21 4 5 Wie kann ich e...

Page 17: ...IKA WIKA gew hrleistet dass die CDs auf denen das Programm aufgezeichnet ist unter normalen Be triebsbedingungen in Materialausf hrung einwandfrei sind Sollten die Datentr ger einen Fehler auf weisen...

Page 18: ...diesem Fall besteht kein Garantieanspruch Der Hersteller bernimmt keinerlei Haftung f r Sch den die an ihren angeschlossenen Ger ten durch den Einsatz des Schnittstellenadapters verursacht werden 7 B...

Page 19: ...it anderen Sensoren kann es zur Zerst rung des Adapters und des Sensors kommen Zum Sensorwechsel ist der Adapter abzustecken Sensoren vor dem Aktiveren des Adapters anstecken sonst wird er vom Adapter...

Page 20: ...ger CP210XVCPInstaller exe Folgen Sie nun den Anweisungen des Installationsprogrammes Stecken Sie den CPA2500 an den USB Anschluss Ihres PCs an Der CPA2500 wird nun automatisch mit dem aktuellen Trei...

Page 21: ...nd der USB to UART Bridge Controller f r die Bereit stellung des COM Ports Rufen Sie bei angestecktem Adapter unter Start Einstellungen Systemsteuerung System Hard ware den Ger temanager auf F r den U...

Page 22: ...onsprogramms Es wird eine neue Programmgruppe mit folgendem Programmsymbol angelegt Mit einem Doppelklick auf dieses Symbol k nnen Sie die Software starten Programm starten w hlen Sie die gew nschte S...

Page 23: ...geschlossene Ger te erkannt Sollte dennoch kein Messadapter gefunden werden berpr fen Sie bitte nochmals folgende Punkte Ist der USB Adapter am USB Port angeschlossen Wurde die richtige Schnittstelle...

Page 24: ...e Messwertaufnahme direkt nach dem Starten Bei den anderen Bedingungen sind entsprechend ein oder mehrere Schwellwerte einzugeben werden diese unter oder berschritten ist die Bedingung je nach gew hlt...

Page 25: ...sp teren Zeitpunkt noch einmal betrachten dann speichern Sie jetzt indem Sie Speichern oder Speichern unter im Men Datei ausw hlen 5 3 5 Aufzeichnung stoppen Wird eine Aufzeichnung gestoppt bleiben di...

Page 26: ...olgenden Dialogfenster Datei exportieren die richtigen Einstellungen zu machen 5 4 2 Daten in die Zwischenablage kopieren Daten in Tabellenform k nnen in die Zwischenablage kopiert werden um in andere...

Page 27: ...len w hlen Sie den Men punkt Diagramm Messreihe hinzuf gen oder das entsprechende Symbol des Diagrammfensters an Es erscheint wieder die Auswahl der Datenquellen und Sie k nnen weitere Messreihen ausw...

Page 28: ...betrachtete Bildausschnitt wieder hergestellt Mit Diagramm Zoom alles wird das gesamte Diagramm wiederhergestellt Der vergr erte Ausschnitt kann mit den Bildlaufleisten nach links rechts oben und unte...

Page 29: ...Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft WIKA Betriebsanleitung Druckmessumformer 29 6 Technische Daten...

Page 30: ...chtlinie 2004 108 EG EN 61326 Emission Gruppe 1 Klasse B und St rfestigkeit beherrschte elektromagnetische Umgebung Dieses Ger t ist f r den Betrieb in beherrschter elektromagnetischer Umgebung entwic...

Page 31: ...Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft WIKA Betriebsanleitung Druckmessumformer 31...

Page 32: ...Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft WIKA Betriebsanleitung Druckmessumformer 32...

Reviews: