5 |
Description of the access point
12
Wieland Electric GmbH | BA001098 | 09/2016 (Rev. A)
5.4.2
Installation position of AP ETH-A-A model version
You can use this model version in metal housings or metal switch cabinets. The position on the mounting rail
does not affect the operation of the device. Position the external WLAN antenna outside the housing.
5.5
User interfaces (connections)
Name
Connection
Description
+
Screw terminal
Connection for +24 V DC power supply
–
Screw terminal
Connection for ground/GND power supply
PE
Screw terminal
Connection for shield grounding
ETH
RJ-45
Connection to the LAN network
ANT *
SMA
Connection for the external WLAN antenna
*only for AP ETH-A-A model version
Tab. 5
Access point connections
Abb. 3
Front view of AP ETH-A model version
Abb. 4
Front view of AP ETH-A-A model version
5.6
State indications
Description
Color
Description
STATUS
green
Does not light up after 10 s:
Remains on:
Flashing:
No power supply available
Access point is ready for use
Access point is starting up
DATA
yellow
Does not light up after 10 s:
LED flickers:
Remains on:
No power supply available or RJ-45 socket not
connected
RJ-45 socket connected with network activity
RJ-45 socket connected without network activity
RES
–
Press RES (< 3 s): Restart access point (reset)
Press RES 5-30 s: Restart with reset to the factory settings
Tab. 6
State indications