5.13. Error messages
If during the work with the machine
the DVS prescriptions are not followed
the necessary steps for the welding process are not correctly or not at all performed
certain measuring devices do not function
an error message will appear on the display.
By pressing the <Enter>-button the error message can be deleted.
Error Cause
Remedial
action
heating element
temperature not o.k. !
Heating element did not yet
set the nominal temperature
and is out of the tolerance of
10 °C / 50 °F
Wait until the heating element
is heated up and the setting
process is performed
pipes clamped too long !!
Pipes are clamped too close
one to the other and the
planer does not fit between
the pipe ends
Clamp the pipes with more
distance one to the other
pipes slipped
in clamps
Pipes were not properly
clamped and are slipping
through the clamping tools
Clamp the pipes tightly
error (PCMCIA) SD-card
Any other SD-card error
Check if SD-card is present or
inserted in a wrong way
error (PCMCIA) SD-card
card full
Memory space of the SD-
card is full
Read out data from the SD-
card and perform new
formatting
error (PCMCIA) SD-card
write protect
SD-card has a write
protection
Remove the write protection of
the SD-card
error (PCMCIA) SD-card
not formatted
SD-card is not formatted and
no data can be stored
Format SD-card with PC and
necessarily
using
„FAT 16”
power failure at last welding
Power supply on the control
unit has been interrupted
during the welding process
Eliminate the cause of the
power supply interruption and
perform a new welding
no welding in
memory
Internal memory is empty
memory full !
internal memory is full (more
than 700 weldings stored)
Copy internal memory onto
SD-card and then delete it
error des. temp.
choose material !
No pipe parameters were set Set pipe parameters
error: check cable
to way measuring !
Travel measuring cable is
not connected or defective
Connect or replace travel
measuring cable
error: pipes not
well in place !
In the depressurized phase
the pipes open the clamping
tools
Prevent the clamping tools
from opening