SECTION 4: IMPORTANT INFORMATION 

SAFETY CUT-OUT: 

The heating element is fitted with a cut-out which will switch off the fire in the event the fire over-
heats, should this occur follow the points below. 
Switch the fire off at the wall outlet, the fire must be isolated from the mains power supply. 
Ensure that there are no obstructions in or around the air inlet or air outlets.

 

After approximately 5 minutes the fire can be switched back on.  

WARNING 

Do not switch the fire on until the above checks have been completed. 
If the fault is persistent contact your retailer or Imperial Fires Customer Service on the telephone 
numbers provided at the beginning of these instructions. 

FEATURES—MANUAL / REMOTE FIRE

 

KEY

 

Standard

 

Option

 

Not available

 

Heat output

 

1.5kW

 

Timer operation

 

 

 

Living flame effect

 

 

 

Thermostat

 

 

 

Digital display

 

 

 

Remote control

 

 

 

Manual control

 

 

 

TECHNICAL SPECIFICATION

 

Voltage 

220 ~240v A.C. 

Power  Input 

1532w 

MAINS CORD:

 

Mains Cord UK Plug 

If the mains supply cord is damaged it must be replaced by a 

competent electrician or similarly qualified person 

FEATURES—LE TIMER FIRE

 

KEY

 

Standard

 

Option

 

Not available

 

Heat output

 

1.5kW

 

Timer operation

 

 

15mins—30mins—1Hr—2Hr

 

Living flame effect

 

 

 

Thermostat

 

 

 

Digital display

 

 

 

Remote control

 

 

 

Manual control

 

 

 

Summary of Contents for Fuego LE Timer fires

Page 1: ...xperience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that the...

Page 2: ...r service agent The wires in the mains supply cord are coloured in accordance with the following code Green and Yellow Earth Blue Neutral Brown Live If your fire is fitted with a moulded on mains plug...

Page 3: ...LIANCE WITHOUT STRETCHING DO NOT USE THIS HEATER WITH AN EXTERNAL PROGRAMME CONTROLLER THERMAL CONTROL TIMER OR ANY OTHER DEVICE WHICH SWITCHES THE HEATER ON AUTOMATICALLY AS A FIRE RISK MAY OCCUR IF...

Page 4: ...3 Mark fixing holes through hanger bar and drill holes to suit wall fixings and screws 4 Fix hanger bar to wall using suitable fixings 5 The main chassis of the fire is now ready to be fitted 7 Connec...

Page 5: ...mains connection should be made at the rear of the aperture If the appliance is to be hard wired allow sufficient length of mains cable to enable removal of the appliance from the aperture with the ca...

Page 6: ...the Facia see below FITTING THE FASCIA The fire front may now be fitted to the fire chassis as follows At the rear of the facia frame there is a large v shaped hook Hook this over the fixing lip loca...

Page 7: ...ERIES ARE FLAT To operate the fire in manual mode follow the steps below NOTE BY PRESSING FLAME MORE THAN ONCE THERE ARE THREE INTENSITY SETTINGS AVAILABLE NOTE THE DISPLAY INDICATES THE TEMPERATURE O...

Page 8: ...te your fire in Remote mode follow the steps below 1 When the Mains supply has been turned on the Fire can be activated to Standby mode by pressing the switch on the Fire as shown 2 To switch the Fire...

Page 9: ...9 OPERATING YOUR FIRE LE TIMER FIRE Not applicable to Manual remote fires To operate the fire follow the steps below NOTE BY PRESSING FLAME MORE THAN ONCE THERE ARE THREE INTENSITY SETTINGS AVAILABLE...

Page 10: ...n antistatic cloth to prevent dust being attracted to the high gloss surfaces of the fire do not use polish For difficult to remove marks such as finger marks it is rec ommended that a chamois leather...

Page 11: ...fault is persistent contact your retailer or Imperial Fires Customer Service on the telephone numbers provided at the beginning of these instructions FEATURES MANUAL REMOTE FIRE KEY Standard Option N...

Page 12: ...ensional Specifications GL Wide GL Standard Height 590mm 575mm Width 720mm 580mm Depth 165mm 165mm Minimum mounting height from floor or surface 60mm Minimum aperture size 535mm High x 440mm Wide GL s...

Page 13: ...13 NOTES...

Page 14: ...14 NOTES...

Page 15: ...you must provide the details requested below otherwise your warranty might be invalid Return this form to your dealer or contact Imperial Fires Limited Imperial Fires Limited reserves the right to re...

Page 16: ...16 I01427 Fuego Issue C...

Reviews: