widinovations Confidential ©
18|41
V
3.3
3.5.
Electrical specifications
The widlaser C500 system, must be connected to a power outlet with the following specifications, 230v AC 16A
50/60Hz. The maximum power consumption of the machine is under 2000w.
Please refer to the machine specifications label for the exact power consumption of your version.
The machine must be grounded, with a ground resistance under 5 Ohms.
3.6.
Component specifications
The widlaser C500 main component specifications are:
LASER
Laser Type
sealed glass tube
30w RF laser
IRADION Z30 RF Laser
Laser Type
CO2 laser
Rated Optical Power (watts)
60w
30w
30w
Wavelength
Material
glass
aluminum
ceramic
Cooling
water cooling
air / water cooling
air / water cooling
Operation temperature
15º - 40º C
5º - 60º C
10º - 40º C
Beam Quality
Beam Divergency
3.1 mrad
7.5 ± 0.5 mrad
< 7mrad (full angle)
Polarization
continued
>100:1 Fixed linear polarization
random
Humidity
0~90%
0~95%
30~85%
Output power tunability
5% 100%
1% 100%
1% 100%
Input Voltage / Current
3.5KV / 24mA
48V DC / 12.5A
48V DC / 12A