![Wickes AQUATRONIC POWER Product Manual Download Page 21](http://html1.mh-extra.com/html/wickes/aquatronic-power/aquatronic-power_product-manual_978792021.webp)
21
Disabling the Temperature Override Button
The temperature override button allows the user to override the preset
maximum temperature. The temperature override button should be
disabled if the power shower is to be used by the young, the elderly, the
infirm, or anyone inexperienced in the correct operation of the controls.
Follow the instructions below to disable the temperature override
button:
1.
Turn the flow control knob
clockwise
to the off position and
the temperature control knob
clockwise
to full cold.
2.
Slide the end of the push-fit release
tool under the flow control knob and
lever the control knob assembly off
the shower unit.
3.
Unclip the concealed end of the
override button from the
temperature indicator trim and
carefully remove the override
button.
4.
Rotate the override button through
half a turn (180°) and refit. Make
sure the override button is flush with
the temperature indicator trim.
5.
Refit the flow control knob in the off
position.
6.
Refit the temperature indicator trim
and temperature control knob.
Ensure the control knob is pushed
onto the temperature hub fully.
7.
The temperature override button is
now disabled.
Temperature
Control Knob
4
7
6
5
3
2
1
Temperature
Indicator Trim
Override Button
Full Cold
Position
Off
Position