3 Specifications
Manufactured to Australian Standard
AS60974-1.
Primary Voltage
220-240 Vac, 50/60 Hz
Rated Primary Current (I
eff
)
10 Amps
Maximum Primary Current (I
max
)
22 Amps
Rated Output @ 40
o
C
Duty cycle based on 10 minute cycle time
Stick
140 Amps, 25.6 V, 20% duty
62 Amps, 22.5 V, 100% duty
TIG
140 Amps, 15.6 V, 20% duty
62 Amps, 12.5 V, 100% duty
Continuous Rated Output @ 40
o
C
63 Amp
Welding Current
20 - 140 Amps
Open Circuit Voltage
VRD Safe 13.5 V (when enabled)
UO = 72 V
Shipping weight
7.0 kg - Includes leads
4.8 kg - Power Source only
If the supply cable is damaged it must
be replaced by the manufacturer, their
service agent or a similarly qualified
person.
IMPORTANT NOTICE: Warranty may
be voided if equipment is powered
from an unsuitable engine driven
generator.
Generators used to power this equipment
must have a minimum capacity of 6 kW
continuous and incorporate output
voltage regulation. Generators without
voltage regulation must have a minimum
capacity of 10 kW.
2 Receiving
Check the equipment received against the
shipping invoice to make sure the shipment
is complete and undamaged. If any damage
has occurred in transit, please immediately
notify your supplier.
The Weldarc inverter package contains;
• Weldarc Inverter Power Source
• Twist-lock Electrode Holder
• Work Clamp 2m
• (This) Operating Manual MC104-40.
Optionally available
• TIG Torch Complete DGT17V3M
with valve, 3m cable with twist-lock
connection and fitted with 2.4mm collet
and thoriated tungsten
• Argon flow gauge regulator REG003