5 Installation

Connection to Electrical Mains Power 
Supply

Negative Wire

Some ‘self-shielded’ flux cored consumable 
wires are operated with the work piece Positive 
and the consumable wire Negative. Refer 
to the manufacturers data for the particular 
consumable wire to be used.

To setup for this condition, connect the ‘WORK’ 
lead plug into the (+) output socket on the 
Power Source, and the ‘WELDING’ lead from 
the wirefeeder into the (-) socket on the Power 
Source, as in Figure 3.

To wirefeeder

To work clamp

To wirefeeder

To work clamp

NOTE. All electrical work shall only be 
undertaken by a qualified electrician.

The Weldmatic Fabricator is supplied with a 
5 metre 4 core 50/0.25 Heavy Duty PVC mains 
power supply cable. This cable should be 
correctly connected to a suitable 3 Phase plug 
top or fixed connection point.

The minimum capacity of the mains wiring and 
power outlet supplying a welder is selected 
according to the effective primary current of 
the machine. The effective primary current for 
a Weldmatic Fabricator is 21 Amps.

The minimum recommended mains circuit 
breaker rating for a Weldmatic Fabricator is 20 
Amps.  

Note : Due to normal variations of sensitivity, 
the tripping time of some 20A circuit breakers 
may limit the duty cycle available from the 
Weldmatic Fabricator. A higher rated circuit 
breaker can be selected, but the mains wiring 
capacity must be increased to suit. 

The current rating of the mains cable depends 
on cable size and method of installation. Refer 
to AS/NZS 3008.1, Table 9. 

If it becomes necessary to replace the mains 
flexible supply cable, use only cable with 
correct current rating. Access to the supply 
terminals is gained by removing the power 
source side panels.

The replacement cable must be fitted and 
retained in the same manner as the original.

Output Voltage Polarity

The design of the Weldmatic Fabricator allows 
selection of the output voltage polarity.

Positive Wire

G.M.A.W. with solid consumable wires is carried 
out with the work piece Negative and the 
welding wire Positive.

To setup for this condition, connect the ‘WORK’ 
lead plug into the (-) output socket on the 
Power Source, and the ‘WELDING’ lead from 
the wirefeeder into the (+) socket on the Power 
Source, as in Figure 2.

Fitting Eye Bolts

Remove 12mm transport bolts and replace with 
supplied eye bolts and fibre washers.

Centralise the internal nut as the eye bolt is 
tightened. Use a bar through the centre of the 
eye bolts to tighten firmly.

Summary of Contents for CP117-2

Page 1: ...dustries Ltd ABN 18 004 547 111 Telephone 1300 300 884 Facsimile 1300 301 884 Email Info welding com au www welding com au Weldmatic Fabricator external wirefeeder Operators Manual Weldmatic Fabricato...

Page 2: ...Weldmatic Fabricator Operators Manual Model No CP117 2 Iss C 05 07 Quality Reliability Performance...

Page 3: ...General Information Page Safe Practices 4 1 Introduction 6 2 Receiving 6 3 Specifications 6 4 Controls 7 5 Installation 8 6 Normal Welding Sequence 9 7 Basic Welding Information 10 8 General Maintenan...

Page 4: ...gas shielded arcs resemble acute sunburn but can be more severe and painful Wear protective clothing leather or heat resistant gloves hat and safety toe boots Button shirt collar and pocket flaps and...

Page 5: ...out of reach of sparks and heat or protect against ignition with suitable and snug fitting fire resistant covers or shields Walls touching combustibles on opposite sides should not be welded on or cut...

Page 6: ...s AUSTMIG ES6 is used with a shielding gas of Carbon Dioxide or Argon mixed with Carbon Dioxide Alternatively Flux cored consumable wires are available in both gas shielded and gasless self shielding...

Page 7: ...g voltage over ten steps 4 Positive Welding Output Terminal 5 Negative Welding Output Terminal 6 Gas Outlet Connector for shielding gas hose from remote wirefeeder 7 Wirefeeder Control Socket Connecto...

Page 8: ...ended mains circuit breaker rating for a Weldmatic Fabricator is 20 Amps Note Due to normal variations of sensitivity the tripping time of some 20A circuit breakers may limit the duty cycle available...

Page 9: ...act and to prevent gas leaks 6 Normal Welding Sequence Weld Start Closing the welding gun switch initiates this sequence of events The gas valve is energised and gas flow commences and continues for a...

Page 10: ...teel Argon 5 to 25 Carbon Dioxide 100 CO2 Aluminium Argon Stainless Steel Argon 1 to 2 Oxygen Consult your gas supplier if more specific information is required Shielding Gas Flow Rate In G M A weldin...

Page 11: ...conditions the equipment covers be removed and any accumulated dust be removed by the use of dry low pressure compressed air or a vacuum cleaner Wirefeed In order to obtain the most satisfactory weld...

Page 12: ...cable work clamp and gun cable assembly 2 Have primary supply circuit checked by a qualified electrician Circuit breaker trips when weld is started or during weld 1 Check the rating of the mains supp...

Page 13: ...Weldmatic Fabricator Operators Manual Model No CP117 2 Iss C 05 07 13 Quality Reliability Performance 10 Circuit Diagram Power Source Fig 7 Power Source Circuit Diagram...

Page 14: ...7 2 Iss C 05 07 Quality Reliability Performance Fig 8 Weldmatic Fabricator Power Source Assembly 11 Assembly and Parts List Weldmatic Fabricator Power Source 7 1 11 7 12 8 4 20 21 18 6 7 13 23 27 28 1...

Page 15: ...position 1 13 E0031 On Off Switch 1 14 CX58 Socket Dinse 2 15 TC265 5 8 UNF Nipple 1 16 TC266 5 8 UNF Nut 1 17 CP15 0 14 Control Socket 1 18 AM272 11N Digital Meter Assembly 1 19 D0024 Rectifier inclu...

Page 16: ...THEORY WHICH BUT FOR THIS PROVISION MIGHT ARISE BY IMPLICATION OPERATION OF LAW CUSTOM OF TRADE OR COURSE OF DEALING INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOS...

Reviews: