SAFETY

The Multiswitches are intended for indoor use only. 

Do not install the Multiswitch in damp, humid, hot or dusty areas.

Switch off and remove the power supply when making connections to the 

Multiswitch to avoid damaging the unit. 

Always earth bond the Multiswitch using the Earth Bonding Lug and/or the 

Earth Terminal Bars to a suitable earth bonding point using minimum 4mm² 

diameter earth cable.

PRECAUTIONS

To ensure trouble free operation: 

Do  not  remove  the  cover  of  the  Multiswitch  or  disassemble  it  as  this will 

invalidate the guarantee.

The female F connectors on this unit were designed for use with '100' type 

coaxial cable with a centre core diameter of 1mm². When using larger CT125 

or CT167 cables, you must ensure that suitable F connectors with reducing 

pins are used otherwise damage to the unit will occur which will invalidate the 

guarantee. 

Do not over tighten the F connectors (finger tight only).

GUARANTEE

 

All Whyte products are guaranteed for a period of 4 years from the date of 

purchase against defects. Within this guarantee period, Whyte Technologies 

will repair or replace the faulty product. In the unlikely event, please return 

any faulty products to your dealer.

The Guarantee will be deemed as void if the serial number on the product 

is removed, damaged or illegible. The Guarantee excludes defects caused by 

incorrect use, accidental damage, disassembly, water/fire/lightning damage or 

lack of ventilation. 

Summary of Contents for WT91-10

Page 1: ...9 Tap Splitter INSTRUCTION MANUAL WT91 10 WS92 05 www whytetechnologies com In the interest of continuous improvement all specifications of products within this brochure are subject to change without...

Page 2: ...CONTENTS Safety Precautions Guarantee General Description Technical Description Example Configuration Specifications 3 3 3 4 5 6 7 2...

Page 3: ...0 type coaxial cable with a centre core diameter of 1mm When using larger CT125 or CT167 cables you must ensure that suitable F connectors with reducing pins are used otherwise damage to the unit will...

Page 4: ...spacing directly interfaces with other Whyte Series 9 products Each Whyte Series 9 Tap comes complete with 9 F Type couplers to enable quick interconnection with Whyte Series 9 products To achieve a...

Page 5: ...d Outputs Whilst the WS92 05 Splitter does not require power to function passive device it has an Auxiliary 18V Input which enables a Whyte Power Supply Unit to be connected thus serving as a convenie...

Page 6: ...y Unit Short Circuit Overload Prorection Model WPSU 2 5A Input 110 240V AC 50 60Hz Output 18V 2 5A WPSU 2 5A WS92 05 DC Block WM932 WM932 WM932 WM932 WM932 WM932 2 5A Power Supply Unit Short Circuit O...

Page 7: ...10 WS92 05 4 Years Warranty 8 SAT 1 TERR Inputs 2 x 8 SAT 1 TERR Outputs LTE Filter rejects 4G interference 18V Auxiliary Input injects power to the HL HH trunk lines Green LED indicates DC power pre...

Page 8: ...Centre Edison Road Enfield EN3 7XF Tel 0330 999 1980 info whytetechnologies com www whytetechnologies com Technical Support North Region Daniel Hawkins MSCTE 07718 654108 dan whytetechnologies com Sou...

Reviews: