WATER DRAINAGE INSTRUCTIONS 

Using a

 portable dehumidifier requires that collected water be emptied frequently. Draining water from this unit 

can be done in 3 different methods:

 

 

1. DRAIN BUCKET METHOD 

 
NOTES:

 

 

1. When the bucket is full, the Full indicator light will light. The com-
pressor and fan will turn off, the Full indicator will light, and a P2 
code will be displayed.

 

 

2. It is recommended to turn the unit off before removing the drain 
bucket.

 

3. Grip the left and right handles of the drain bucket securely and 
carefully pull out the drain bucket. Do not put the drain bucket on the 
floor because the bottom of the bucket is not even which may cause 
the water to spill.  See Fig.3 and Fig. 4.

 

4. Remove the water from the drain bucket and replace it back to the 
dehumidifier. The drain bucket must be installed properly and se-
curely seated for the dehumidifier to operate.

 

5. The machine will restart when the drain bucket is restored in its 
correct position. If the unit was turned off prior to the removal of the 
drain bucket, press the Power button to restore operation.

 

 

When you remove the drain bucket, do not touch any inside parts of 
the unit. Doing so may damage the product and result to injury.

 

 

 

Be sure to push the drain bucket gently all the way into the unit. 
Banging the bucket against anything or failing to push it in securely 
may cause the unit not to operate.

 

 

If the pump filter drops when you remove the bucket (see Fig.5), you 
must reinstall the pump filter properly to the unit before replacing the 
drain bucket into the unit (see Fig.6). 

 

 

Upon replacing the bucket, firmly push the bucket in place until it 
locks. There should be no gaps between the bucket and the dehu-
midifier. 

 

 

When the drain bucket is removed, the unit will beep 8 times and the 
digital display shows 

Eb

.  

Eb 

is an error code that indicates that 

the drain bucket is removed or not positioned correctly. Make sure 
that the drain bucket is properly installed and the in right position.

 

Fig. 3 

Fig. 4 

Fig. 5 

Fig. 6 

Pump filter 

Push up pump filter in place 

Summary of Contents for ELITE D Series

Page 1: ...nsure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference Model RPD 950DNP INSTRUCTION MANUAL WHYNTER ELITE D...

Page 2: ...be obtained from your local municipal authority Thank you for choosing the Whynter Portable Dehumidifier Please follow the instructions provided in this user guide to obtain the very best performance...

Page 3: ...SAFETY PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS AND CONTROLS 6 9 OPERATION INSTRUCTIONS 10 11 WATER DRAINAGE INSTRUCTIONS 12 13 MAINTENANCE 14 TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 1...

Page 4: ...adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements Do not use multip...

Page 5: ...ir intake and outlet Do not place the appliance in front of curtains or drapes to ensure they do not obstruct the air intake Keep curtains blinds or drapes closed during the sunniest part of the day C...

Page 6: ...uous Gravity Drain hose 2 16 5 ft pump drain hose 3 Power Cord Buckle Power Cord Buckle Installation For easy storage install the power cord buckle to the rear of the unit Once installed the power cor...

Page 7: ...ly 250 hours of operation To reset after cleaning the filter press the Filter button and the light will turn off 4 Turbo Button Press the Turbo button to engage Turbo Fan mode The Turbo indicator ligh...

Page 8: ...y pressing the and buttons Once Timer Delay Switch On is placed press the Timer button again to activate Auto stop function and the Timer OFF light will come on Set the desired time delay OFF hours by...

Page 9: ...temperature is below 41 F Display The display screen shows a number of different indications depending on the selection function Shows the set relative humidity level from 35 RH to 85 RH Once the RH i...

Page 10: ...and spores WARNING NEVER OPERATE THE DEHUMIDIFIER WITHOUT THE FILTER START OPERATION 1 Ensure that the appliance is connected to the power socket 2 Make sure the drain bucket is placed in proper posi...

Page 11: ...maximum performance Allow at least 10 of air space on all sides of the appliance for good air circulation and 20 or more above the appliance NOTE Dehumidifiers working in a basement will have little o...

Page 12: ...in bucket is restored in its correct position If the unit was turned off prior to the removal of the drain bucket press the Power button to restore operation When you remove the drain bucket do not to...

Page 13: ...e drain bucket is full NOTE The Pump Indicator Light will flash when there is a failure in the pump operation Please turn off the unit and unplug the power cord and check the following points Clean th...

Page 14: ...e bucket in a dishwasher 3 Cleaning the air filter To ensure the air intake is filtered properly and to assure that your dehumidifi er runs efficiently it is recommended to clean the air filter at lea...

Page 15: ...r home is musty you will want to use your portable dehumidifier especially if you have respiratory trouble or allergies This unit can also help relieve symptoms by controlling the relative humidity in...

Page 16: ...aced in a space that does not restrict air flowing into the rear coil or out of the front grille Set the RH level and the appliance will stop when the set RH is reached The dehumidifier runs but the r...

Page 17: ...want to remove more moisture set the unit on Continuous operation Empty drain bucket and insert the bucket to the appliance properly The pump indicator light blinks Water pump filter is dirty Water p...

Page 18: ......

Page 19: ......

Page 20: ...consumer misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by r...

Reviews: