background image

13 

WATER DRAINAGE INSTRUCTIONS 

2. CONTINUOUS / GRAVITY DRAIN METHOD  

Water can be automatically emptied into a floor drain by attaching the 20” continuous/gravity drain hose to the con-
tinuous/gravity drain outlet. To use gravity to drain your portable dehumidifier, it must be installed on a level surface 
or at least 12 inches above the ground, on a sturdy table or shelf unit. When using the function of continuous/
gravity drainage, your drain hose must be placed horizontally below the drainage hole. Avoid uneven ground and 
folding the hose.

 

NOTE: When using continuous/gravity drainage setup, there may be some water collected in the water in the drain 
bucket

 

1. Remove the continuous drain cover and then attach the 20” con-
tinuous/gravity drain hose. Make sure the hose is securely fastened 
to prevent leakage.

 

 

2. Direct the drain hose toward a drain or other suitable drainage 
outlet. Make sure that there are no distortions with the hose that may 
stop the water flow.  (See Fig. 7)

 

3. 

Select the desired humidity setting and fan speed on the unit for 

continuous draining to start.  

 

3. WATER PUMP METHOD 

One of the key features of this dehumidifier is that it has a water pump that pushes water up or over a longer dis-
tance. Using this feature will enable your unit to run maintenance free. 

 

NOTE: The water pump will ONLY engage when the drain bucket is full. 

NOTE: The Pump Indicator Light will flash when there is a failure in the 
pump operation. Please turn off the unit and unplug the power cord and 
check the following points: 
•  

Clean the pump filter 

- remove the drain bucket from the unit, pull down 

the pump filter, and clean (See Fig. 9)

 

•  Check the pump drain hose for kinks or obstructions

 

•  Reinstall the pump filter and drain bucket properly. Turn on the unit. If 
the error repeats, call for service

 

•  Do not use this operation when the outdoor temperature is equal to or 
less than 32°F. Otherwise, water hose may be blocked as the water will 
turn to ice and cause the unit to fail. When the pump drain feature is not 
being used, remove the pump drain hose from the outlet.

 

1. Make sure the continuous/gravity drain assembly is removed from 
the continuous/gravity drain outlet and the plastic cover is installed. 

 

 

2. Insert the 16 ft. pump drain hose (included) into the bottom pump 
drain outlet (See Fig. 8), then lead the drain hose to a suitable drain-
age facility. Make sure that the hose is fully inserted to avoid water 
leakage and no kinks which will cause the water to stop flowing. 

 

3. Press the Pump button to activate the pump operation.

 

NOTE: The water pump will ONLY engage when the drain bucket is 
full.  

 

4. The water pump may make some noise when it starts to work with-
in the first 3 

- 5 minutes. This is a part of the unit’s normal operation.  

 

5. Select the desired humidity setting and fan speed on the unit.  

 

Fig. 7 

Fig. 8 

Pump Drain 
Outlet 

Pump Drain 
Hose 

Fig. 9 

Pump filter 

Summary of Contents for ELITE D Series

Page 1: ...nsure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference Model RPD 950DNP INSTRUCTION MANUAL WHYNTER ELITE D...

Page 2: ...be obtained from your local municipal authority Thank you for choosing the Whynter Portable Dehumidifier Please follow the instructions provided in this user guide to obtain the very best performance...

Page 3: ...SAFETY PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS AND CONTROLS 6 9 OPERATION INSTRUCTIONS 10 11 WATER DRAINAGE INSTRUCTIONS 12 13 MAINTENANCE 14 TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 1...

Page 4: ...adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements Do not use multip...

Page 5: ...ir intake and outlet Do not place the appliance in front of curtains or drapes to ensure they do not obstruct the air intake Keep curtains blinds or drapes closed during the sunniest part of the day C...

Page 6: ...uous Gravity Drain hose 2 16 5 ft pump drain hose 3 Power Cord Buckle Power Cord Buckle Installation For easy storage install the power cord buckle to the rear of the unit Once installed the power cor...

Page 7: ...ly 250 hours of operation To reset after cleaning the filter press the Filter button and the light will turn off 4 Turbo Button Press the Turbo button to engage Turbo Fan mode The Turbo indicator ligh...

Page 8: ...y pressing the and buttons Once Timer Delay Switch On is placed press the Timer button again to activate Auto stop function and the Timer OFF light will come on Set the desired time delay OFF hours by...

Page 9: ...temperature is below 41 F Display The display screen shows a number of different indications depending on the selection function Shows the set relative humidity level from 35 RH to 85 RH Once the RH i...

Page 10: ...and spores WARNING NEVER OPERATE THE DEHUMIDIFIER WITHOUT THE FILTER START OPERATION 1 Ensure that the appliance is connected to the power socket 2 Make sure the drain bucket is placed in proper posi...

Page 11: ...maximum performance Allow at least 10 of air space on all sides of the appliance for good air circulation and 20 or more above the appliance NOTE Dehumidifiers working in a basement will have little o...

Page 12: ...in bucket is restored in its correct position If the unit was turned off prior to the removal of the drain bucket press the Power button to restore operation When you remove the drain bucket do not to...

Page 13: ...e drain bucket is full NOTE The Pump Indicator Light will flash when there is a failure in the pump operation Please turn off the unit and unplug the power cord and check the following points Clean th...

Page 14: ...e bucket in a dishwasher 3 Cleaning the air filter To ensure the air intake is filtered properly and to assure that your dehumidifi er runs efficiently it is recommended to clean the air filter at lea...

Page 15: ...r home is musty you will want to use your portable dehumidifier especially if you have respiratory trouble or allergies This unit can also help relieve symptoms by controlling the relative humidity in...

Page 16: ...aced in a space that does not restrict air flowing into the rear coil or out of the front grille Set the RH level and the appliance will stop when the set RH is reached The dehumidifier runs but the r...

Page 17: ...want to remove more moisture set the unit on Continuous operation Empty drain bucket and insert the bucket to the appliance properly The pump indicator light blinks Water pump filter is dirty Water p...

Page 18: ......

Page 19: ......

Page 20: ...consumer misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by r...

Reviews: