INSTALLATION, OPERATION & MAINTENANCE MANUAL WH3778
11
-SO Sensor Operation
Range Adjustment
1. Make sure power supply is disconnected from
sensor and make short circuit on red wires.
See DETAIL A.
2. Connect power supply to sensor. Red light should
be flashing.
4. Move hand to desired sensing distance.
See DETAIL B.
3. Move hand in front of sensor to distance of 2 to 4
"
"
within 5 seconds and wait until red light flashes
quickly.
5. Hold hand at desired sensing distance until red light
stops flashing and solenoid activates.
See DETAIL C.
DETAIL A
DETAIL B
DETAIL C
Jumper
By Others
OPTIONAL WH3775-SOV SENSOR OPERATED FAUCET
NOTES:
LIGATURE RESISTANT SPOUT
9VDC INFRARED SENSOR
9VDC SOLENOID DUAL-TEMP VALVE ASSEMBLY
CHECKSTOP/STRAINER ASSEMBLY
1/2" NPS INLET FLEX HOSE
1.
2.
3.
4.
5.
9VDC PLUG-IN TRANSFORMER
6.
9VDC BATTERY PACK (OPTIONAL)
7.
BLUE (COLD) TEMPERATURE INDICATOR
8.
RED (TEMPERED) TEMPERATURE INDICATOR
9.
WIRING HARNESS
10.
4"
[102]
SHOWN
2" [51]
MAX
2
2
8
9
OPTIONAL -BAT BATTERY
OPERATION DETAIL
1
7
6
3
4
5
10
-SO Sensor Operation or
-PPZ Programmable Piezo Pushbutton
Transformer must
be plugged into a
GFI protected
circuit. Fixture must
be earth grounded
per N.E.C. or
applicable codes.