background image

WHITEHALL MANUFACTURING

 • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A

Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

INSTALLATION, OPERATION & MAINTENANCE MANUAL WH3778

6900-218-001  New: 05/27/2021

Model WH3778

®

Go to 

 to fill out eWarranty Registration, keyword search: WARRANTY.

www.whitehallmfg.com

This warranty does not cover installation or labor charges, and does not apply to materials which have been damaged by 
other causes such as mishandling or improper care or abnormal use.

 The repair or replacement of the defective materials 

shall constitute the sole remedy of the Buyer and the sole remedy of Whitehall under this warranty. Whitehall shall not be liable 
under any circumstances for incidental, consequential or direct charges caused by defects in the materials, or any delay in the 
repair or replacement thereof. This warranty is in lieu of all other warranties expressed or implied. Product maintenance instructions 
are issued with each fixture, and disregard or non-compliance with these instructions will constitute an abnormal use condition and 
void the warranty. If you have any questions or require technical assistance, please call 800-743-8219.

Whitehall Manufacturing Company warrants that its products are free from defects in material or workmanship under normal use 
and service for a period of one year from date of shipment. Whitehall's liability under this warranty shall be discharged solely by 
replacement or repair of defective material, provided Whitehall is notified in writing within one year from date of shipment, F.O.B. 
Industry, California.

NOTICE TO KEEP ORIGINAL PACKAGING-

 Regarding warranty claims: customer must retain original packaging for one year 

upon receipt of product. If packaging is discarded, it is the customer's responsibility to provide adequate packaging. Any shipping 
claims that are a direct result of customer-provided packaging materials will be handled by the shipper.

WARRANTY INFORMATION

LIGATURE RESISTANT 

TM

CORTERRA  OFFSET 
VANITY ADA COMPLIANT

WH3778L-WH3375-HC-SO

Ÿ

 

Patent Pending

Important: Some options may slightly alter installation. To ensure proper installation review the manual 
thoroughly and verify rough-ins before beginning any work. File this manual with the owner or maintenance 
personnel upon completion of installation.

Single Temp Valve Assembly: Recommended working water pressure is 30 psi (2.07 bars) minimum to 100 
psi  (6.89  bars)  maximum.  Maximum  temperature  is  130°F  (54.4°C).  Maximum  outlet  temperature 
recommended is 105°F (40.6°C). Valve assembly must be drained prior to being subjected to freezing 
temperatures. A checkstop is provided with this valve assembly.

T/P Mixing Valve Assembly: Recommended working water pressure is 30 psi (2.07 bars) minimum to 100 
psi (6.89 bars) maximum. Maximum hot water temperature is 180°F (82°C). Temperature adjustment range 
is  85-115°F  (29-46°C).  Minimum  hot  water  supply  temperature  must  be  5°F  (3°C)  above  desired  set 
temperature. Valve assembly must be drained prior to being subjected to freezing temperatures. The valve 
assembly has checks integral to the inlets however, angle stops are to be provided by the installer.

Industry standard wall backing, for wall hung fixtures, is required. Installer provided wall anchors and wall 
anchoring hardware must be appropriate for wall construction.

ANSI, UFAS or ADA compliance is subject to the interpretation and requirements of the local code authority 
and is the responsibility of the installer for verification.

Teflon tape is recommended on all threaded waste and supply connections to reduce the possibility of leaks.

Prior to installation, supply lines must be flushed of all foreign material such as pipe dope, chips, or solder. 
Debris or foreign material in water supply may damage valve.

Provide  110-120VAC/60Hz/3A  (MAX)  electrical  receptacle  for  factory  supplied  120VAC/9VDC,  100mA 
plug-in transformer. 

NOTE: Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per N.E.C. 
(National Electrical Code). 

(Photo shows optional accessories)

Summary of Contents for WH3778

Page 1: ...will be handled by the shipper WARRANTY INFORMATION LIGATURE RESISTANT TM CORTERRA OFFSET VANITY ADA COMPLIANT WH3778L WH3375 HC SO Patent Pending Important Some options may slightly alter installati...

Page 2: ...00 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com INSTALLATION OPERATION MAINTENANCE MANUAL WH3778 2 ACCESSIBILITY OVERVIEW ADA Adult 22 27 Min 4 34 Rim Max 213 4 16 ADA ages 6 thru 1...

Page 3: ...IONS SHOWN ARE FOR RECOMMENDED ADULT HEIGHT ADJUST VERTICAL DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL STATE LOCAL CODES STOP VALVE NOT PROVIDED 1 2 3 NOTE FIXTURE WEIGHT IS APPROXIMATELY 90 LBS W...

Page 4: ...ngle Stops by others 1 4 Wall Mounting Points 5 When required for Sensor Faucet 120VAC 60Hz 3A Max GFCI Protected Electrical Receptacle A B C D E 9 16 Deck Channel Mounting Points 2 Places F WH3778R W...

Page 5: ...681 Fax 626 855 4862 Web www whitehallmfg com INSTALLATION OPERATION MAINTENANCE MANUAL WH3778 5 CARRIER DIMENSION INFORMATION 14 1 4 4 2 2 131 4 37 VIEW NOT TO SCALE SUPPORT KNUCKLES VERTICAL SUPPORT...

Page 6: ...e Horizontal Support Assembly onto Vertical Supports 4 so that upper mounting points 5 are at desired location see chart and secure with 1 4 20 Set Screws 3 and position carrier in desired location 2...

Page 7: ...horing hardware By others See DETAIL A Hang Deck Assembly against 2Finished Wall and slide down wall until the Deck Mounting Channel rests on Frame Mounting Channel See DETAIL B Secure Deck Assembly t...

Page 8: ...h basin assemble gasket washer and jam nut as shown to strainer and tighten securely Add close elbow to strainer assembly as indicated HINT Teflon tape is recommended on all threaded waste and supply...

Page 9: ...gn material such as pipe dope pipe chips solder sand etc DUAL TEMP WITH MXTP VALVE For MXTP Valve Hot Cold Flush Supply lines AConnect installer provided 1 2 NPS flex hoses to valve Attach Single Temp...

Page 10: ...using 1 2 NPTE connections 4 Turn on hot and cold water supplies If any leaks are observed hand tighten connections as necessary to stop leaks before proceeding 5 Turn on fixture and allow water to fl...

Page 11: ...quickly 5 Hold hand at desired sensing distance until red light stops flashing and solenoid activates See DETAIL C DETAIL A DETAIL B DETAIL C Jumper By Others OPTIONAL WH3775 SOV SENSOR OPERATED FAUCE...

Page 12: ...INSTALLATION OPERATION MAINTENANCE MANUAL WH3778 12 ACCESS PANEL INSTALLATION See DETAIL A Install P Trap Cover using 10 32 x 61 2 Hex Screws Provided See DETAIL B Secure bottom of P Trap Cover to wal...

Page 13: ...CE Acorn s densified solid surface material is composed of recycled solid surface polymer resin aluminum trihydrate and fillers It is resistant to stains impact and burns and complies with ANSI Z124 3...