 INSTALLER/CONFIGURATION MENU

1

 Step

Press        or        to select:

COMMENTS

Displayed (Factory Default)

Press Button(s)

2

(SL)

FA

5

6

7

8

 LOC

(OFF)

on

0 HI

(0)

4 LO to

4 HI

(F)

C

10

Select Compressor lockout OFF or ON

Select temperature displa

y adjustment higher or lower

Select temperature display to F or C

4

d-L

(on)

OFF

Select displa

y bac

klight OFF or ON

Filter

(000)

0 to 1950 hours

(in 50 hour increments)

Select filter replacement r

un time

Select FA or SL (Fast or Slow) pump cycle rate

Configuration Menu

3

EMER

(FA)

SL

Select FA or SL (Fast or Slow) A

uxiliary and 

Emergency A

ux heating cycle rate

and

and

and

9

FA

(on)

OFF

Select fast second-stage ON or OFF

and

and

and

and

and

Set SYSTEM

s

witch to OFF

SYSTEM switch must be OFF to configure ther

mostat options

Set SYSTEM s

witch 

to HEAT or COOL

Returns to normal operation

* Press          and

           to advance to next item

CONFIGURATION MENU

The configuration menu allows you to set certain thermostat 
operating characteristics to your system or personal require-
ments.

Move SYSTEM switch to the OFF position, then press 

 and 

 at the same time to enter the configuration menu. The 

display will show the first item in the configuration menu.

The configuration menu chart summarizes the configuration 
options. An explanation of each option follows.
Press 

 and 

 to change to the next menu item. To exit 

the menu, move the SYSTEM switch to HEAT or COOL. If no 
keys are pressed within fifteen minutes, the thermostat will exit 

the configuration menu.

2)  Select  FA or SL (Fast or Slow) Heat Pump stage Cycle 

Rate - The FA setting is used to produce shorter heating cycles. 
The SL setting produces a longer heating/cooling cycle. Both 

settings produce very accurate temperature control and can be 

set to your personal preference. FA cycles the system just under 
.75°F and the SL setting cycles at approximately 1.2°F.  

3)  Select FA or SL (Fast or Slow) Auxiliary or Emergency Cycle 

Rate - The FA setting is frequently used for gas, oil or electric 
heat. The SL setting produces a longer heating cycle. Both set

-

tings produce very accurate temperature control and can be set 

to your personal preference. FA cycles the system just under 
.6°F and the SL setting cycles at approximately 1.°F.  

4)  Select  backlit  display  (d-L  OFF  or  ON)

  -  The  display 

backlight improves display contrast in low lighting conditions. 
Selecting backlight ON will keep the light on continuously. 
Selecting OFF will keep the light off.

5)  Select filter replacement run time

 - The thermostat will 

display 

FILTER 

after a set time of operation. This is a re-

minder to change or clean your air filter. This time can be 

set from 0 to 1950 hours in 50 hour increments. 

A selection 

of 000 will cancel this feature. 

When 

FLTR

 is displayed, 

you can clear it by pressing 

 and 

 at the same time. 

This resets the timer and starts counting the hours until the 

next filter change. Contact your heat pump manufacturer for 
a specific replacement/maintenance interval.

6)  Select Compressor Lockout (LOC OFF or ON) - Selecting 

LOC ON will cause the thermostat to wait 5 minutes before 

turning on the compressor if the heating and cooling system 

loses power. It will also wait 5 minutes minimum between cool

-

ing cycles. This is intended to help protect the compressor from 

short cycling. Some newer compressors already have a time 

delay built in and do not require this feature. Your compressor 
manufacturer can tell you if the feature is already present in 
their  system.  When  the  thermostat  compressor  time  delay 
occurs it will flash the 

Snowflake

 or 

Flame

 icon for about 

five minutes. 

7)  Select Temperature Display Adjustment (4 LO to 4 HI)

 - 

Allows you to adjust the room temperature display up to 4° 

higher or lower. Your thermostat was accurately calibrated 
at the factory but you have the option to change the display 
temperature to match your previous thermostat. The current 
or adjusted room temperature will be displayed on the right 
side of the display. 

8)  Select Temperature Display (°F or °C) - Changes the display 

readout to Celsius or Fahrenheit as required. The current 

room temperature will be displayed on the right side of the 
display. 

9)  Select Fast second stage - In the RUN mode, if the tem

-

perature  is  manually  raised  by  3°F  (2°C)  or  more  above 

room  temperature  using 

  and  the  fast  second  stage 

feature is enabled, FA on, the second stage will energize 
immediately. With FA off, the second stage will not energize 
until the setpoint temperature is 10°F or more above room 

temperature.

Summary of Contents for 1F89-211

Page 1: ...sformer systems Optional AA batteries to provide continuous temperature display during loss of AC power SPECIFICATIONS ELECTRICAL DATA Electrical Rating 20 to 30 VAC 50 60 Hz or D C 0 05 to 1 0 Amps L...

Page 2: ...oca tions on wall using base as a template 4 Move base out of the way Drill mounting holes 5 Fasten base loosely to wall as shown in fig 1 using two mounting screws Place a level against bottom of bas...

Page 3: ...ly one of the systems remove the transformer of the system with NO safety circuits NOTE Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency See Note L R E SYSTEM MONITOR...

Page 4: ...to adjust temperature setting above room tem perature The cooling system should stop operating THERMOSTAT QUICK REFERENCE 2 1 3 4 5 8 10 6 9 5 8 7 Figure 5 Thermostat display buttons and switches SU...

Page 5: ...just under 6 F and the SL setting cycles at approximately 1 F 4 Select backlit display d L OFF or ON The display backlight improves display contrast in low lighting conditions Selecting backlight ON...

Page 6: ...et to Fan On 4 Check each wire connection to verify they are not shorted or touching together No bare wire should stick out from under terminal screws Try resetting the thermostat as described above I...

Page 7: ...7 NOTES...

Page 8: ...ww white rodgers com www emersonclimate com Homeowner Help Line 1 800 284 2925 White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric C...

Reviews: