INTERMITTENT PILOT ELECTRONIC SYSTEM OPERATING INSTRUCTIONS
The electronic control valve system includes the ability to switch
the pilot from a standing pilot mode to an intermittent pilot mode.
•
IPI Mode
- In the Intermittent Pilot mode when the unit is
turned ON, it will cause spark to the pilot, light the pilot,
then allow the burner to light. When the unit is turned
OFF, both the burner and pilot will turn OFF.
•
CPI Mode
- In Continuous Pilot mode the pilot remains
ON when the burner is turned OFF.
Note: A small toggle switch is located on the front of the module
tray switches from IPI (left) to the CPI (right).
See Figure 62.
When the unit is turned ON, the electrical current will energize a
spark to the pilot igniter. Once the pilot sensor heats up (after a
few seconds), the valve will be energized, allowing gas to flow to
the burner.
1. Follow the SAFETY and LIGHTING INSTRUCTIONS for In-
termittent Pilot controls found in this manual, and on labels
found in the control compartment located in the lower cavity
of the appliance.
2. During the heating season (or in power outage periods), it is
recommended that the pilot remain in the CPI (standing pilot
mode) to reduce cold start issues, and/or conserve battery
backup power during a power outage.
3. The gas valve has inlet and outlet pressure taps as shown in
Figure 62.
Refer to Page 13 for gas pressure requirements.
Note:
The gas control has a manual HI/LO flame adjustment
knob.
See Figure 62.
Rotate the HI/LO knob counter-
clockwise to “HI” to increase the flame height, and clock-
wise to “LO” to decrease the flame height. The BTU
change from HI to LO is 37,000 BTU to 26,000 BTU.
OPTIONAL REMOTE CONTROLS
Optional remote controls are available for use with this appliance.
Place the remote receiver in a wall outlet box with extended wir-
ing, on the fireplace hearth, behind the left side surround panel,
or in the control compartment area as far forward in the insert as
possible.
The placement options for the remote receiver are given to allow
flexibility, however battery life will be extended when the receiver
is placed in a cool area.
To connect the remote receiver to the appliance, first disconnect
the ON/OFF switch wires from the white and green wire connec-
tors and connect the wires from the remote receiver to the green
and white wire connectors. See Page 53.
Follow the instructions included with the remote control for pro-
gramming and operating.
SENSOR
MANUAL
HI/LO
REGULATOR
GAS VALVE
OUTLET
PRESSURE
TAP
INLET
PRESSURE
TAP
MODULE TRAY
9 PIN CONNECTOR
SPARK ROD
GROUND
MANUAL ON/OFF SWITCH
NOTE: ADDITIONAL ON/OFF SWITCH & WIRING INCLUDED
PILOT SELECTOR SWITCH
IPI - INTERMITANT PILOT (LEFT)
CPI - CONTINUOUS PILOT (RIGHT)
AA (4)
BATTERY
BACKUP
PILOT
ASSEMBLY
IGNITOR
Figure 62